Teletype 3.0 RC5 Documentation
Introduction
Teletype is a dynamic, musical event triggering platform.
- Teletype Studies - guided series of tutorials
PDF command reference chart — PDF scene recall sheet — Default scenes
Current version: .0 — Firmware update procedure
What’s new?
Version 3.0
Major new features
Grid Integration
Grid integration allows you to use grid to visualize, control and execute teletype scripts. You can create your own UIs using grid ops, or control Teletype directly with the Grid Control mode. Built in Grid Visualizer allows designing and using grid scenes without a grid. For more information and examples of grid scenes please see the Grid Studies. Important: do NOT plug your grid directly into Teletype! Doing so may damage your module. Grid must be powered externally.
Improved script editing
You can now select multiple lines when editing scripts by holding shift
. You can move the current selection up and down with alt-<up>
and alt-<down>
. You can copy/cut/paste a multiline selection as well. To delete selected lines without copying into the clipboard use alt-<delete>
.
Three level undo is also now available with ctrl-z
shortcut.
Support for the Orthogonal Devices ER-301 Sound Computer over i2c
You now can connect up to three ER-301s via i2c and address up to 100 virtual CV channels and 100 virtual TR channels per ER-301. (The outputs range 1-100, 101-200, and 201-300 respectively.) To function, this requires a slight mod to current in-market ER-301s and a specialized i2c cable that reorders two of the pins. Find more information on the Orthogonal Devices ER-301 Wiki Teletype Integration Page.
Support for the 16n Faderbank via i2c
The 16n Faderbank is an open-source sixteen fader controller with support for USB MIDI, standard MIDI, and i2c communication with the Teletype. It operates just like an IN or PARAM (or the TXi for that matter) in that you read values from the device. You use the operator FADER (or the alias FB) and the number of the slider you wish to poll (1-16). Know that longer cables may require that you use a powered bus board even if you only have one device on your Teletype’s i2c bus. (You will know that you have a problem if your Teletype randomly hangs on reads.)
Support for the SSSR Labs SM010 Matrixarchate via i2c
The SSSR Labs SM010 Matrixarchate is a 16x8 IO Sequenceable Matrix Signal Router. Teletype integration allows you to switch programs and control connections. For a complete list of available ops refer to the manual. Information on how to connect the module can be found in the SM010 manual.
Support for W/ via i2c
Support for controlling Whimsical Raps W/ module via i2c. See the respective section for a complete list of available ops and refer to https://www.whimsicalraps.com/pages/w-type for more details.
New operators
? x y z
is a ternary “if” operator, it will select between y
and z
based on the condition x
.
New pattern ops
P.MIN
PN.MIN
P.MAX
PN.MAX
return the position for the first smallest/largest value in a pattern between the START
and END
points.
P.RND
/ PN.RND
return a randomly selected value in a pattern between the START
and END
points.
P.+
/ PN.+
/ P.-
/ PN.-
increment/decrement a pattern value by the specified amount.
P.+W
/ PN.+W
/ P.-W
/ PN.-W
same as above and wrap to the specified range.
New Telex ops
TO.CV.CALIB
allows you to lock-in an offset across power cycles to calibrate your TELEX CV output (TO.CV.RESET
removes the calibration).
TO.ENV
now accepts gate values (1/0) to trigger the attack and decay.
New Kria ops
KR.CV x
get the current CV value for channel x
KR.MUTE x
KR.MUTE x y
get/set mute state for channel x
KR.TMUTE x
toggle mute state for channel x
KR.CLK x
advance the clock for channel x
Ops for ER-301, 16n Faderbank, SM010, W/
Too many to list, please refer to their respective sections.
New aliases
$
for SCRIPT
RND
/ RRND
RAND
/ RRAND
WRP
for WRAP
SCL
for SCALE
New keybindings
Hold shift
while making line selection in script editing to select multiple lines. Use alt-<up>
and alt-<down>
to move selected lines up and down. Copy/cut/paste shortcuts work with multiline selection as well. To delete selected lines without copying into the clipboard use alt-<delete>
.
While editing a line you can now use ctrl-<left>
/ ctrl-<right>
to move by words.
ctrl-z
provides three level undo in script editing.
Additional Alt-H
shortcut is available to view the Help screen.
Alt-G
in Live mode will turn on the Grid Visualizer, which has its own shortcuts. Refer to the Keys section for a complete list.
The keybindings to insert a scaled knob value in the Tracker mode were changed from ctrl
to ctrl-alt
and from shift
to ctrl-shift
.
Bug fixes
i2c initialization delayed to account for ER-301 bootup
last screen saved to flash
knob jitter when loading/saving scenes reduced
duplicate commands not added to history
SCALE
precision improved
PARAM
set properly when used in the init script
PARAM
and IN
won’t reset to 0 after INIT.DATA
PN.HERE
, P.POP
, PN.POP
will update the tracker screen
P.RM
/ PN.RM
will not change pattern length if deleting outside of length range
TIME
and LAST
are now 1ms accurate
RAND
/ RRAND
will properly work with large range values
New behavior
Previously, when pasting the clipboard while in script editing the pasted line would replace the current line. It will now instead push the current line down. This might result in some lines being pushed beyond the script limits - if this happens, use ctrl-z
to undo the change, delete some lines and then paste again.
I
would previously get initialized to 0 when executing a script. If you called a script from another script’s loop this meant you had to use a variable to pass the loop’s current I
value to the called script. This is not needed anymore - when a script is called from another script its I
value will be set to the current I
value of the calling script.
Version 2.2
Teletype version 2.2 introduces Chaos and Bitwise operators, Live mode view of variables, INIT operator, ability to calibrate CV In and Param knob and set Min/Max scale values for both, a screensaver, Random Number Generator, and a number of fixes and improvements.
Major new features
Chaos Operators
The CHAOS
operator provides a new source of uncertainty to the Teletype via chaotic yet deterministic systems. This operator relies on various chaotic maps for the creation of randomized musical events. Chaotic maps are conducive to creating music because fractals contain a symmetry of repetition that diverges just enough to create beautiful visual structures that at times also apply to audio. In mathematics a map is considered an evolution function that uses polynomials to drive iterative procedures. The output from these functions can be assigned to control voltages. This works because chaotic maps tend to repeat with slight variations offering useful oscillations between uncertainty and predictability.
Bitwise Operators
Bitwise operators have been added to compliment the logic functions and offer the ability to maximize the use of variables available on the Teletype.
Typically, when a variable is assigned a value it fully occupies that variable space; should you want to set another you’ll have to use the next available variable. In conditions where a state of on, off, or a bitwise mathematical operation can provide the data required, the inclusion of these operators give users far more choices. Each variable normally contains 16 bits and Bitwise allows you to BSET
, BGET
, and BCLR
a value from a particular bit location among its 16 positions, thus supplying 16 potential flags in the same variable space.
INIT
The new op family INIT
features operator syntax for clearing various states from the unforgiving INIT with no parameters that clears ALL state data (be careful as there is no undo) to the ability to clear CV, variable data, patterns, scenes, scripts, time, ranges, and triggers.
Live Mode Variable Display
This helps the user to quickly check and monitor variables across the Teletype. Instead of single command line parameter checks the user is now able to simply press the ~ key
(Tilde) and have a persistent display of eight system variables.
Screensaver
Screen saver engages after 90 minutes of inactivity
New Operators
• IN.SCALE min max
sets the min/max values of the CV Input jack • PARAM.SCALE min max
set the min/max scale of the Parameter Knob • IN.CAL.MIN
sets the zero point when calibrating the CV Input jack • IN.CAL.MAX
sets the max point (16383) when calibrating the CV Input jack • PARAM.CAL.MIN
sets the zero point when calibrating the Parameter Kob • PARAM.CAL.MAX
sets the max point (16383) when calibrating the Parameter Kob • R
generate a random number • R.MIN
set the low end of the random number generator • R.MAX
set the upper end of the random number generator
Fixes
• Multiply now saturates at limits (-32768 / 32767) while previous behavior returned 0 at overflow • Entered values now saturate at Int16 limits which are -32768 / 32767 • Reduced flash memory consumption by not storing TEMP script • I now carries across DEL
commands • Corrected functionality of JI
(Just Intonation) op for 1V/Oct tuning • Reduced latency of IN
op
Improvements
• Profiling code (optional developer feature) • Screen now redraws only lines that have changed
Version 2.1
Teletype version 2.1 introduces new operators that mature the syntax and capability of the Teletype, as well as several bug fixes and enhancement features.
Major new features
Tracker Data Entry Improvements
Data entry in the tracker screen is now buffered, requiring an ENTER
keystroke to commit changes, or SHIFT-ENTER
to insert the value. All other navigation keystrokes will abandon data entry. The increment / decrement keystrokes (]
and [
), as well as the negate keystroke (-
) function immediately if not in data entry mode, but modify the currently buffered value in edit mode (again, requiring a commit).
Turtle Operator
The Turtle operator allows 2-dimensional access to the patterns as portrayed out in Tracker mode. It uses new operators with the @
prefix. You can @MOVE X Y
the turtle relative to its current position, or set its direction in degrees with @DIR
and its speed with @SPEED
and then execute a @STEP
.
To access the value that the turtle operator points to, use @
, which can also set the value with an argument.
The turtle can be constrained on the tracker grid by setting its fence with @FX1
, @FY1
, @FX2
, and @FY2
, or by using the shortcut operator @F x1 y1 x2 y2
. When the turtle reaches the fence, its behaviour is governed by its fence mode, where the turtle can simply stop (@BUMP
), wrap around to the other edge (@WRAP
), or bounce off the fence and change direction (@BOUNCE
). Each of these can be set to 1
to enable that mode.
Setting @SCRIPT N
will cause script N
to execute whenever the turtle crosses the boundary to another cell. This is different from simply calling @STEP; @SCRIPT N
because the turtle is not guaranteed to change cells on every step if it is moving slowly enough.
Finally, the turtle can be displayed on the tracker screen with @SHOW 1
, where it will indicate the current cell by pointing to it from the right side with the <
symbol.
New Mods: EVERY, SKIP, and OTHER, plus SYNC
These mods allow rhythmic division of control flow. EVERY X: executes the post-command once per X at the Xth time the script is called. SKIP X: executes it every time but the Xth. OTHER: will execute when the previous EVERY/SKIP command did not.
Finally, SYNC X will set each EVERY and SKIP counter to X without modifying its divisor value. Using a negative number will set it to that number of steps before the step. Using SYNC -1 will cause each EVERY to execute on its next call, and each SKIP will not execute.
Script Line “Commenting”
Individual lines in scripts can now be disabled from execution by highlighting the line and pressing ALT-/
. Disabled lines will appear dim. This status will persist through save/load from flash, but will not carry over to scenes saved to USB drive.
New Operators
W [condition]:
is a new mod that operates as a while loop. The BREAK
operator stops executing the current script BPM [bpm]
returns the number of milliseconds per beat in a given BPM, great for setting M
. LAST [script]
returns the number of milliseconds since script
was last called.
New Operator Behaviour
SCRIPT
with no argument now returns the current script number. I
is now local to its corresponding L
statement. IF/ELSE
is now local to its script.
New keybindings
CTRL-1
through CTRL-8
toggle the mute status for scripts 1 to 8 respectively. CTRL-9
toggles the METRO script. SHIFT-ENTER
now inserts a line in Scene Write mode.
Bug fixes
Temporal recursion now possible by fixing delay allocation issue, e.g.: DEL 250: SCRIPT SCRIPT KILL
now clears TR
outputs and stops METRO. SCENE
will no longer execute from the INIT script on initial scene load. AVG
and Q.AVG
now round up from offsets of 0.5 and greater.
Breaking Changes
As I
is now local to L
loops, it is no longer usable across scripts or as a general-purpose variable. As IF/ELSE
is now local to a script, scenes that relied on IF in one script and ELSE in another will be functionally broken.
Version 2.0
Teletype version 2.0 represents a large rewrite of the Teletype code base. There are many new language additions, some small breaking changes and a lot of under the hood enhancements.
Major new features
Sub commands
Several commands on one line, separated by semicolons.
e.g. CV 1 N 60; TR.PULSE 1
See the section on “Sub commands” for more information.
Aliases
For example, use TR.P 1
instead of TR.PULSE 1
, and use + 1 1
, instead of ADD 1 1
.
See the section on “Aliases” for more information.
PN
versions of every P
OP
There are now PN
versions of every P
OP
. For example, instead of:
P.I 0
P.START 0
P.I 1
P.START 10
You can use:
PN.START 0 0
PN.START 1 10
TELEXi and TELEXo OP
s
Lots of OP
s have been added for interacting with the wonderful TELEXi input expander and TELEXo output expander. See their respective sections in the documentation for more information.
New keybindings
The function keys can now directly trigger a script.
The <tab>
key is now used to cycle between live, edit and pattern modes, and there are now easy access keys to directly jump to a mode.
Many new text editing keyboard shortcuts have been added.
See the “Modes” documentation for a listing of all the keybindings.
USB memory stick support
You can now save you scenes to USB memory stick at any time, and not just at boot up. Just insert a USB memory stick to start the save and load process. Your edit scene should not be effected.
It should also be significantly more reliable with a wider ranger of memory sticks.
WARNING: Please backup the contents of your USB stick before inserting it. Particularly with a freshly flashed Teletype as you will end up overwriting all the saved scenes with blank ones.
Other additions
- Limited script recursion now allowed (max recursion depth is 8) including self recursion.
- Metro scripts limited to 25ms, but new
M!
op to set it as low as 2ms (at your own risk), see “Metronome”OP
section for more.
Breaking changes
Removed the need for the
II
OP
.For example,
II MP.PRESET 1
will become justMP.PRESET 1
.Merge
MUTE
andUNMUTE
OP
s toMUTE x
/MUTE x y
.See the documentation for
MUTE
for more information.Remove unused Meadowphysics
OP
s.Removed:
MP.SYNC
,MP.MUTE
,MP.UNMUTE
,MP.FREEZE
,MP.UNFREEZE
.Rename Ansible Meadowphysics
OP
s to start withME
.This was done to avoid conflicts with the Meadowphysics
OP
s.
WARNING: If you restore your scripts from a USB memory stick, please manually fix any changes first. Alternatively, incorrect commands (due to the above changes) will be skipped when imported, please re-add them.
Known issues
Visual glitches
The cause of these is well understood, and they are essentially harmless. Changing modes with the <tab>
key will force the screen to redraw. A fix is coming in version 2.1.
Quickstart
Panel
The keyboard is attached to the front panel, for typing commands. The commands can be executed immediately in LIVE mode or assigned to one of the eight trigger inputs in EDIT mode. The knob and in jack can be used to set and replace values.
LIVE mode
Teletype starts up in LIVE mode. You’ll see a friendly > prompt, where commands are entered. The command:
TR.TOG A
will toggle trigger A after pressing enter. Consider:
CV 1 V 5
CV 2 N 7
CV 1 0
Here the first command sets CV 1 to 5 volts. The second command sets CV 2 to note 7 (which is 7 semitones up). The last command sets CV 1 back to 0.
Data flows from right to left, so it becomes possible to do this:
CV 1 N RAND 12
Here a random note between 0 and 12 is set to CV 1.
We can change the behavior of a command with a PRE such as DEL
:
DEL 500 : TR.TOG A
TR.TOG A
will be delayed by 500ms upon execution.
A helpful display line appears above the command line in dim font. Here any entered commands will return their numerical value if they have one.
SCRIPTS, or several lines of commands, can be assigned to trigger inputs. This is when things get musically interesting. To edit each script, we shift into EDIT mode.
LIVE mode icons
Four small icons are displayed in LIVE mode to give some important feedback about the state of Teletype. These icons will be brightly lit when the above is true, else will remain dim. They are, from left to right:
- Slew: CV outputs are currently slewing to a new destination.
- Delay: Commands are in the delay queue to be executed in the future.
- Stack: Commands are presently on the stack waiting for execution.
- Metro: Metro is currently active and the Metro script is not empty.
EDIT mode
Toggle between EDIT and LIVE modes by pushing TAB.
The prompt now indicates the script you’re currently editing:
1
-8
indicates the script associated with corresponding triggerM
is for the internal metronomeI
is the init script, which is executed upon scene recall
Script 1 will be executed when trigger input 1 (top left jack on the panel) receives a low-to-high voltage transition (trigger, or front edge of a gate). Consider the following as script 1:
1:
TR.TOG A
Now when input 1 receives a trigger, TR.TOG A
is executed, which toggles the state of output trigger A.
Scripts can have multiple lines:
1:
TR.TOG A
CV 1 V RAND 4
Now each time input 1 receives a trigger, CV 1 is set to a random volt between 0 and 4, in addition to output trigger A being toggled.
Metronome
The M
script is driven by an internal metronome, so no external trigger is required. By default the metronome interval is 1000ms. You can change this readily (for example, in LIVE mode):
M 500
The metronome interval is now 500ms. You can disable/enable the metronome entirely with M.ACT
:
M.ACT 0
Now the metronome is off, and the M
script will not be executed. Set M.ACT
to 1 to re-enable.
Patterns
Patterns facilitate musical data manipulation– lists of numbers that can be used as sequences, chord sets, rhythms, or whatever you choose. Pattern memory consists four banks of 64 steps. Functions are provided for a variety of pattern creation, transformation, and playback. The most basic method of creating a pattern is by directly adding numbers to the sequence:
P.PUSH 5
P.PUSH 11
P.PUSH 9
P.PUSH 3
P.PUSH
adds the provided value to the end of the list– patterns keep track of their length, which can be read or modified with P.L
. Now the pattern length is 4, and the list looks something like:
5, 11, 9, 3
Patterns also have an index P.I
, which could be considered a playhead. P.NEXT
will advance the index by one, and return the value stored at the new index. If the playhead hits the end of the list, it will either wrap to the beginning (if P.WRAP
is set to 1, which it is by default) or simply continue reading at the final position.
So, this script on input 1 would work well:
1:
CV 1 N P.NEXT
Each time input 1 is triggered, the pattern moves forward one then CV 1 is set to the note value of the pattern at the new index. This is a basic looped sequence. We could add further control on script 2:
2:
P.I 0
Since P.I
is the playhead, trigger input 2 will reset the playhead back to zero. It won’t change the CV, as that only happens when script 1 is triggered.
We can change a value within the pattern directly:
P 0 12
This changes index 0 to 12 (it was previously 5), so now we have 12, 11, 9, 3.
We’ve been working with pattern 0
up to this point. There are four pattern banks, and we can switch banks this way:
P.N 1
Now we’re on pattern bank 1. P.NEXT
, P.PUSH
, P
, (and several more commands) all reference the current pattern bank. Each pattern maintains its own play index, wrap parameter, length, etc.
We can directly access and change any pattern value with the command PN
:
PN 3 0 22
Here the first argument (3) is the bank, second (0) is the index, and last is the new value (22). You could do this by doing P.N 3
then P 0 22
but there are cases where a direct read/write is needed in your patch.
Check the Command Set section below for more pattern commands.
Patterns are stored in flash with each scene!
TRACKER mode
Editing patterns with scripts or from the command line isn’t always ergonomic. When you’d like to visually edit patterns, TRACKER mode is the way.
The TAB
key cycles between LIVE, EDIT and TRACKER mode. You can also get directly to TRACKER mode by pressing the NUM LOCK
key. TRACKER mode is the one with 4 columns of numbers on the Teletype screen.
The current pattern memory is displayed in these columns. Use the arrow keys to navigate. Holding ALT will jump by pages.
The edit position is indicated by the brightest number. Very dim numbers indicate they are outside the pattern length.
Use the square bracket keys [
and ]
to decrease/increase the values. Backspace sets the value to 0. Entering numbers will overwrite a new value. You can cut/copy/paste with ALT-X-C-V.
Check the Keys section for a complete list of tracker shortcuts.
Scenes
A SCENE is a complete set of scripts and patterns. Stored in flash, scenes can be saved between sessions. Many scenes ship as examples. On startup, the last used scene is loaded by Teletype.
Access the SCENE menu using ESCAPE
. The bracket keys ([
and ]
) navigate between the scenes. Use the up/down arrow keys to read the scene text. This text will/should describe what the scene does generally along with input/output functions. ENTER
will load the selected scene, or ESCAPE
to abort.
To save a scene, hold ALT
while pushing ESCAPE
. Use the brackets to select the destination save position. Edit the text section as usual– you can scroll down for many lines. The top line is the name of the scene. ALT-ENTER
will save the scene to flash.
Keyboard-less Scene Recall
To facilitate performance without the need for the keyboard, scenes can be recalled directly from the module’s front panel.
- Press the
SCENE RECALL
button next to the USB jack on the panel. - Use the
PARAM
knob to highlight your desired preset. - Hold the
SCENE RECALL
button for 1 second to load the selected scene.
Init Script
The INIT script (represented as I
) is executed when a preset is recalled. This is a good place to set initial values of variables if needed, like metro time M
or time enable TIME.ACT
for example.
USB Backup
Teletype’s scenes can be saved and loaded from a USB flash drive. When a flash drive is inserted, Teletype will recognize it and go into disk mode. First, all 32 scenes will be written to text files on the drive with names of the form tt##s.txt
. For example, scene 5 will be saved to tt05s.txt
. The screen will display WRITE.......
as this is done.
Once complete, Teletype will attempt to read any files named tt##.txt
and load them into memory. For example, a file named tt13.txt
would be loaded as scene 13 on Teletype. The screen will display READ......
Once this process is complete, Teletype will return to LIVE mode and the drive can be safely removed.
For best results, use an FAT-formatted USB flash drive. If Teletype does not recognize a disk that is inserted within a few seconds, it may be best to try another.
An example of possible scenes to load, as well as the set of factory default scenes, can be found at the Teletype Codex.
Commands
Nomenclature
- SCRIPT – multiple commands
- COMMAND – a series (one line) of words
- WORD – a text string separated by a space: value, operator, variable, mod
- VALUE – a number
- OPERATOR – a function, may need value(s) as argument(s), may return value
- VARIABLE – named memory storage
- MOD – condition/rule that applies to rest of the command, e.g.: del, prob, if, s
Syntax
Teletype uses prefix notation. Evaluation happens from right to left.
The left value gets assignment (set). Here, temp variable X
is assigned zero:
X 0
Temp variable Y
is assigned to the value of X
:
Y X
X
is being read (get X
), and this value is being used to set Y
.
Instead of numbers or variables, we can use operators to perform more complex behavior:
X TOSS
TOSS
returns a random state, either 0 or 1 on each call.
Some operators require several arguments:
X ADD 1 2
Here ADD
needs two arguments, and gets 1 and 2. X
is assigned the result of ADD
, so X
is now 3.
If a value is returned at the end of a command, it is printed as a MESSAGE. This is visible in LIVE mode just above the command prompt. (In the examples below ignore the // comments).
8 // prints 8
X 4
X // prints 4
ADD 8 32 // prints 40
Many parameters are indexed, such as CV and TR. This means that CV and TR have multiple values (in this case, each has four.) We pass an extra argument to specify which index we want to read or write.
CV 1 0
Here CV 1 is set to 0. You can leave off the 0 to print the value.
CV 1 // prints value of CV 1
Or, this works too:
X CV 1 // set X to current value of CV 1
Here is an example of using an operator RAND
to set a random voltage:
CV 1 V RAND 4
First a random value between 0 and 3 is generated. The result is turned into a volt with a table lookup, and the final value is assigned to CV 1.
The order of the arguments is important, of course. Consider:
CV RRAND 1 4 0
RRAND
uses two arguments, 1 and 4, returning a value between these two. This command, then, chooses a random CV output (1-4) to set to 0. This might seem confusing, so it’s possible to clarify it by pulling it apart:
X RRAND 1 4
CV X 0
Here we use X
as a temp step before setting the final CV.
With some practice it becomes easier to combine many functions into the same command.
Furthermore, you can use a semicolon to include multiple commands on the same line:
X RRAND 1 4; CV X 0
This is particularly useful in INIT scripts where you may want to initialize several values at once:
A 66; X 101; TR.TIME 1 20;
Continuing
Don’t forget to checkout the Teletype Studies for an example-driven guide to the language.
Keys
Global key bindings
These bindings work everywhere.
Key | Action |
---|---|
<tab> |
change modes, live to edit to pattern and back |
<esc> |
preset read mode, or return to last mode |
alt-<esc> |
preset write mode |
win-<esc> |
clear delays, stack and slews |
shift-alt-? / alt-h |
help text, or return to last mode |
<F1> to <F8> |
run corresponding script |
<F9> |
run metro script |
<F10> |
run init script |
alt-<F1> to alt-<F8> |
edit corresponding script |
alt-<F9> |
edit metro script |
alt-<F10> |
edit init script |
ctrl-<F1> to ctrl-<F8> |
mute/unmute corresponding script |
ctrl-<F9> |
enable/disable metro script |
<numpad-1> to <numpad-8> |
run corresponding script |
<num lock> / <F11> |
jump to pattern mode |
<print screen> / <F12> |
jump to live mode |
Text editing
These bindings work when entering text or code.
In most cases, the clipboard is shared between live, edit and the 2 preset modes.
Key | Action |
---|---|
<left> / ctrl-b |
move cursor left |
<right> / ctrl-f |
move cursor right |
ctrl-<left> |
move left by one word |
ctrl-<right> |
move right by one word |
<home> / ctrl-a |
move to beginning of line |
<end> / ctrl-e |
move to end of line |
<backspace> / ctrl-h |
backwards delete one character |
<delete> / ctrl-d |
forwards delete one character |
shift-<backspace> / ctrl-u |
delete from cursor to beginning |
shift-<delete> / ctrl-e |
delete from cursor to end |
alt-<backspace> / ctrl-w |
delete from cursor to beginning of word |
ctrl-x / alt-x |
cut to clipboard |
ctrl-c / alt-c |
copy to clipboard |
ctrl-v / alt-v |
paste to clipboard |
Live mode
Key | Action |
---|---|
<down> / C-n |
history next |
<up> / C-p |
history previous |
<enter> |
execute command |
~ |
toggle variables |
[ / ] |
switch to edit mode |
alt-g |
toggle grid visualizer |
alt-<arrows> |
move grid cursor |
alt-shift-<arrows> |
select grid area |
alt-<space> |
emulate grid press |
alt-/ |
switch grid pages |
alt-\ |
toggle grid control view |
alt-<prt sc> |
insert grid x/y/w/h |
In full grid visualizer mode pressing alt
is not required.
Edit mode
In edit mode multiple lines can be selected and used with the clipboard.
Key | Action |
---|---|
<down> / C-n |
line down |
<up> / C-p |
line up |
[ |
previous script |
] |
next script |
<enter> |
enter command |
shift-<enter> |
insert command |
alt-/ |
toggle line comment |
shift-<up> |
expand selection up |
shift-<down> |
expand selection down |
alt-<delete> |
delete selection |
alt-<up> |
move selection up |
alt-<down> |
move selection down |
ctrl-z |
undo (3 levels) |
Tracker mode
The tracker mode clipboard is independent of text and code clipboard.
Key | Action |
---|---|
<down> |
move down |
alt-<down> |
move a page down |
<up> |
move up |
alt-<up> |
move a page up |
<left> |
move left |
alt-<left> |
move to the very left |
<right> |
move right |
alt-<right> |
move to the very right |
[ |
decrement by 1 |
] |
increment by 1 |
<backspace> |
delete a digit |
shift-<backspace> |
delete an entry, shift numbers up |
<enter> |
commit edit (increase length if cursor in position after last entry) |
shift-<enter> |
commit edit, then duplicate entry and shift downwards (increase length as <enter> ) |
alt-x |
cut value (n.b. ctrl-x not supported) |
alt-c |
copy value (n.b. ctrl-c not supported) |
alt-v |
paste value (n.b. ctrl-v not supported) |
shift-alt-v |
insert value |
shift-l |
set length to current position |
alt-l |
go to current length entry |
shift-s |
set start to current position |
alt-s |
go to start entry |
shift-e |
set end to current position |
alt-e |
go to end entry |
- |
negate value |
<space> |
toggle non-zero to zero, and zero to 1 |
0 to 9 |
numeric entry |
shift-2 (@ ) |
toggle turtle display marker (< ) |
ctrl-alt |
insert knob value scaled to 0..31 |
ctrl-shift |
insert knob value scaled to 0..1023 |
Preset read mode
Key | Action |
---|---|
<down> / C-n |
line down |
<up> / C-p |
line up |
<left> / [ |
preset down |
<right> / ] |
preset up |
<enter> |
load preset |
Preset write mode
Key | Action |
---|---|
<down> / C-n |
line down |
<up> / C-p |
line up |
[ |
preset down |
] |
preset up |
<enter> |
enter text |
shift-<enter> |
insert text |
alt-<enter> |
save preset |
Help mode
Key | Action |
---|---|
<down> / C-n |
line down |
<up> / C-p |
line up |
<left> / [ |
previous page |
<right> / ] |
next page |
OPs and MODs
Variables
General purpose temp vars: X
, Y
, Z
, and T
.
T
typically used for time values, but can be used freely.
A
-D
are assigned 1-4 by default (as a convenience for TR labeling, but TR can be addressed with simply 1-4). All may be overwritten and used freely.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
A |
A x |
get / set the variable A , default 1 |
|
B |
B x |
get / set the variable B , default 2 |
|
C |
C x |
get / set the variable C , default 3 |
|
D |
D x |
get / set the variable D , default 4 |
|
DRUNK |
DRUNK x |
changes by -1 , 0 , or 1 upon each read saving its state, setting will give it a new value for the next read |
|
DRUNK.MIN |
DRUNK.MIN x |
set the lower bound for DRUNK , default 0 |
|
DRUNK.MAX |
DRUNK.MAX x |
set the upper bound for DRUNK , default 255 |
|
DRUNK.WRAP |
DRUNK.WRAP x |
should DRUNK wrap around when it reaches it’s bounds, default 0 |
|
FLIP |
FLIP x |
returns inverted state (0 or 1 ) on each read (also settable) |
|
I |
I x |
get / set the variable I |
|
O |
O x |
auto-increments after each access, can be set, starting value 0 |
|
O.INC |
O.INC x |
how much to increment O by on each invocation, default 1 |
|
O.MIN |
O.MIN x |
the lower bound for O , default 0 |
|
O.MAX |
O.MAX x |
the upper bound for O , default 63 |
|
O.WRAP |
O.WRAP x |
should O wrap when it reaches its bounds, default 1 |
|
T |
T x |
get / set the variable T , typically used for time, default 0 |
|
TIME |
TIME x |
timer value, counts up in ms., wraps after 32s, can be set | |
TIME.ACT |
TIME.ACT x |
enable or disable timer counting, default 1 |
|
LAST x |
get value in milliseconds since last script run time | ||
X |
X x |
get / set the variable X , default 0 |
|
Y |
Y x |
get / set the variable Y , default 0 |
|
Z |
Z x |
get / set the variable Z , default 0 |
DRUNK
DRUNK
/DRUNK x
Changes by -1
, 0
, or 1
upon each read, saving its state. Setting DRUNK
will give it a new value for the next read, and drunkedness will continue on from there with subsequent reads.
Setting DRUNK.MIN
and DRUNK.MAX
controls the lower and upper bounds (inclusive) that DRUNK
can reach. DRUNK.WRAP
controls whether the value can wrap around when it reaches it’s bounds.
I
I
/I x
Get / set the variable I
, this variable is overwritten by L
, but can be used freely outside an L
loop. Each script gets its own I
variable, so if you call a script from another script’s loop you can still use and modify I
without affecting the calling loop. In this scenario the script getting called will have its I
value initialized with the calling loop’s current I
value.
O
O
/O x
Auto-increments by O.INC
after each access. The initial value is 0
. The lower and upper bounds can be set by O.MIN
(default 0
) and O.MAX
(default 63
). O.WRAP
controls if the value wraps when it reaches a bound (default is 1
).
Example:
O => 0
O => 1
X O
X => 2
O.INC 2
O => 3 (O increments after it's accessed)
O => 5
O.INC -2
O 2
O => 2
O => 0
O => 63
O => 61
LAST
LAST x
Gets the number of milliseconds since the current script was run. From the live mode, shows time elapsed since last run of I script.
For example, one-line tap tempo:
M LAST SCRIPT
Running this script twice will set the metronome to be the time between runs.
Hardware
The Teletype trigger inputs are numbered 1-8, the CV and trigger outputs 1-4. See the Ansible documentation for details of the Ansible output numbering when in Teletype mode.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
CV x |
CV x y |
CV target value | |
CV.OFF x |
CV.OFF x y |
CV offset added to output | |
CV.SET x |
Set CV value | ||
CV.SLEW x |
CV.SLEW x y |
Get/set the CV slew time in ms | |
IN |
Get the value of IN jack (0-16383) | ||
IN.SCALE min max |
Set static scaling of the IN CV to between min and max . |
||
PARAM |
PRM |
Get the value of PARAM knob (0-16383) | |
PARAM.SCALE min max |
Set static scaling of the PARAM knob to between min and max . |
||
IN.CAL.MIN |
Reads the input CV and assigns the voltage to the zero point | ||
IN.CAL.MAX |
Reads the input CV and assigns the voltage to the max point | ||
PARAM.CAL.MIN |
Reads the Parameter Knob minimum position and assigns a zero value | ||
PARAM.CAL.MAX |
Reads the Paramter Knob maximum position and assigns the maximum point | ||
TR x |
TR x y |
Set trigger output x to y (0-1) | |
TR.POL x |
TR.POL x y |
Set polarity of trigger output x to y (0-1) | |
TR.TIME x |
TR.TIME x y |
Set the pulse time of trigger x to y ms | |
TR.TOG x |
Flip the state of trigger output x | ||
TR.PULSE x |
TR.P |
Pulse trigger output x | |
MUTE x |
MUTE x y |
Disable trigger input x | |
STATE x |
Read the current state of input x |
CV
CV x
/CV x y
Get the value of CV associated with output x
, or set the CV output of x
to y
.
CV.OFF
CV.OFF x
/CV.OFF x y
Get the value of the offset added to the CV value at output x
. The offset is added at the final stage. Set the value of the offset added to the CV value at output x
to y
.
CV.SET
CV.SET x
Set the CV value at output x
bypassing any slew settings.
CV.SLEW
CV.SLEW x
/CV.SLEW x y
Get the slew time in ms associated with CV output x
. Set the slew time associated with CV output x
to y
ms.
IN
IN
Get the value of the IN jack. This returns a valuue in the range 0-16383.
PARAM
PARAM
- alias:
PRM
Get the value of the PARAM knob. This returns a valuue in the range 0-16383.
IN.CAL.MIN
IN.CAL.MIN
- Connect a patch cable from a calibrated voltage source
- Set the voltage source to 0 volts
- Execute IN.CAL.MIN from the live terminal
- Call IN and confirm the 0 result
IN.CAL.MAX
IN.CAL.MAX
- Set the voltage source to target maximum voltage (10V)
- Execute IN.CAL.MAX from the live terminal
- Call IN and confirm that the result is 16383
PARAM.CAL.MIN
PARAM.CAL.MIN
- Turn the PARAM knob all the way to the left
- Execute PARAM.CAL.MIN from the live terminal
- Call PARAM and confirm the 0 result
PARAM.CAL.MAX
PARAM.CAL.MAX
- Turn the knob all the way to the right
- Execute PARAM.CAL.MAX from the live terminal
- Call PARAM and verify that the result is 16383
TR
TR x
/TR x y
Get the current state of trigger output x
. Set the state of trigger output x
to y
(0-1).
TR.POL
TR.POL x
/TR.POL x y
Get the current polarity of trigger output x
. Set the polarity of trigger output x
to y
(0-1). When TR.POL = 1, the pulse is 0 to 1 then back to 0. When TR.POL = 0, the inverse is true, 1 to 0 to 1.
TR.TIME
TR.TIME x
/TR.TIME x y
Get the pulse time of trigger output x
. Set the pulse time of trigger output x
to y
ms.
TR.TOG
TR.TOG x
Flip the state of trigger output x
.
TR.PULSE
TR.PULSE x
- alias:
TR.P
Pulse trigger output x.
MUTE
MUTE x
/MUTE x y
Mute the trigger input on x
(0-7) when y
is non-zero.
STATE
STATE x
Read the current state of trigger input x
(0=low, 1=high).
Patterns
Patterns facilitate musical data manipulation– lists of numbers that can be used as sequences, chord sets, rhythms, or whatever you choose. Pattern memory consists four banks of 64 steps. Functions are provided for a variety of pattern creation, transformation, and playback.
New in teletype 2.0, a second version of all Pattern ops have been added. The original P
ops (P
, P.L
, P.NEXT
, etc.) act upon the ‘working pattern’ as defined by P.N
. By default the working pattern is assigned to pattern 0 (P.N 0
), in order to execute a command on pattern 1 using P
ops you would need to first reassign the working pattern to pattern 1 (P.N 1
).
The new set of ops, PN
(PN
, PN.L
, PN.NEXT
, etc.), include a variable to designate the pattern number they act upon, and don’t effect the pattern assignment of the ‘working pattern’ (ex: PN.NEXT 2
would increment pattern 2 one index and return the value at the new index). For simplicity throughout this introduction we will only refer to the P
ops, but keep in mind that they now each have a PN
counterpart (all of which are detailed below)
Both patterns and their arrays of numbers are indexed from 0. This makes the first pattern number 0, and the first value of a pattern is index 0. The pattern index (P.I
) functions like a playhead which can be moved throughout the pattern and/or read using ops: P
, P.I
, P.HERE
, P.NEXT
, and P.PREV
. You can contain pattern movements to ranges of a pattern and define wrapping behavior using ops: P.START
, P.END
, P.L
, and P.WRAP
.
Values can be edited, added, and retrieved from the command line using ops: P
, P.INS
, P.RM
, P.PUSH
, P.HERE
, P.NEXT
, and P.PREV
. Some of these ops will additionally impact the pattern length upon their execution: P.INS
, P.RM
, P.PUSH
, and P.POP
.
To see your current pattern data use the <tab>
key to cycle through live mode, edit mode, and pattern mode. In pattern mode each of the 4 patterns is represented as a column. You can use the arrow keys to navigate throughout the 4 patterns and their 64 values. For reference a key of numbers runs the down the lefthand side of the screen in pattern mode displaying 0-63.
From a blank set of patterns you can enter data by typing into the first cell in a column. Once you hit <enter>
you will move to the cell below and the pattern length will become one step long. You can continue this process to write out a pattern of desired length. The step you are editing is always the brightest. As you add steps to a pattern by editing the value and hitting <enter>
they become brighter than the unused cells. This provides a visual indication of the pattern length.
The start and end points of a pattern are represented by the dotted line next to the column, and the highlighted dot in this line indicates the current pattern index for each of the patterns. See the key bindings for an extensive list of editing shortcuts available within pattern mode.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
P.N |
P.N x |
get/set the pattern number for the working pattern, default 0 |
|
P x |
P x y |
get/set the value of the working pattern at index x |
|
PN x y |
PN x y z |
get/set the value of pattern x at index y |
|
P.L |
P.L x |
get/set pattern length of the working pattern, non-destructive to data | |
PN.L x |
PN.L x y |
get/set pattern length of pattern x. non-destructive to data | |
P.WRAP |
P.WRAP x |
when the working pattern reaches its bounds does it wrap (0/1 ), default 1 (enabled) |
|
PN.WRAP x |
PN.WRAP x y |
when pattern x reaches its bounds does it wrap (0/1 ), default 1 (enabled) |
|
P.START |
P.START x |
get/set the start location of the working pattern, default 0 |
|
PN.START x |
PN.START x y |
get/set the start location of pattern x , default 0 |
|
P.END |
P.END x |
get/set the end location of the working pattern, default 63 |
|
PN.END x |
PN.END x y |
get/set the end location of the pattern x , default 63 |
|
P.I |
P.I x |
get/set index position for the working pattern. | |
PN.I x |
PN.I x y |
get/set index position for pattern x |
|
P.HERE |
P.HERE x |
get/set value at current index of working pattern | |
PN.HERE x |
PN.HERE x y |
get/set value at current index of pattern x |
|
P.NEXT |
P.NEXT x |
increment index of working pattern then get/set value | |
PN.NEXT x |
PN.NEXT x y |
increment index of pattern x then get/set value |
|
P.PREV |
P.PREV x |
decrement index of working pattern then get/set value | |
PN.PREV x |
PN.PREV x y |
decrement index of pattern x then get/set value |
|
P.INS x y |
insert value y at index x of working pattern, shift later values down, destructive to loop length |
||
PN.INS x y z |
insert value z at index y of pattern x , shift later values down, destructive to loop length |
||
P.RM x |
delete index x of working pattern, shift later values up, destructive to loop length |
||
PN.RM x y |
delete index y of pattern x , shift later values up, destructive to loop length |
||
P.PUSH x |
insert value x to the end of the working pattern (like a stack), destructive to loop length |
||
PN.PUSH x y |
insert value y to the end of pattern x (like a stack), destructive to loop length |
||
P.POP |
return and remove the value from the end of the working pattern (like a stack), destructive to loop length | ||
PN.POP x |
return and remove the value from the end of pattern x (like a stack), destructive to loop length |
||
P.MIN |
find the first minimum value in the pattern between the START and END for the working pattern and return its index | ||
PN.MIN x |
find the first minimum value in the pattern between the START and END for pattern x and return its index |
||
P.MAX |
find the first maximum value in the pattern between the START and END for the working pattern and return its index | ||
PN.MAX x |
find the first maximum value in the pattern between the START and END for pattern x and return its index |
||
P.RND |
return a value randomly selected between the start and the end position | ||
PN.RND x |
return a value randomly selected between the start and the end position of pattern x |
||
P.+ x y |
increase the value of the working pattern at index x by y |
||
PN.+ x y z |
increase the value of pattern x at index y by z |
||
P.- x y |
decrease the value of the working pattern at index x by y |
||
PN.- x y z |
decrease the value of pattern x at index y by z |
||
P.+W x y a b |
increase the value of the working pattern at index x by y and wrap it to a ..b range |
||
PN.+W x y z a b |
increase the value of pattern x at index y by z and wrap it to a ..b range |
||
P.-W x y a b |
decrease the value of the working pattern at index x by y and wrap it to a ..b range |
||
PN.-W x y z a b |
decrease the value of pattern x at index y by z and wrap it to a ..b range |
P.N
P.N
/P.N x
get/set the pattern number for the working pattern, default 0
. All P
ops refer to this pattern.
P
P x
/P x y
get/set the value of the working pattern at index x
. All positive values (0-63
) can be set or returned while index values greater than 63 clip to 63. Negative x
values are indexed backwards from the end of the pattern length of the working pattern.
Example:
with a pattern length of 6 for the working pattern:
P 10
retrieves the working pattern value at index 6
P.I -2
retrieves the working pattern value at index 4
This applies to PN
as well, except the pattern number is the first variable and a second variable specifies the index.
P.WRAP
P.WRAP
/P.WRAP x
when the working pattern reaches its bounds does it wrap (0/1
). With PN.WRAP
enabled (1
), when an index reaches its upper or lower bound using P.NEXT
or P.PREV
it will wrap to the other end of the pattern and you can continue advancing. The bounds of P.WRAP are defined through P.L
, P.START
, and P.END
.
If wrap is enabled (P.WRAP 1
) a pattern will begin at its start location and advance to the lesser index of either its end location or the end of its pattern length
Examples:
With wrap enabled, a pattern length of 6, a start location of 2 , and an end location of 8.
P.WRAP 1; P.L 6; P.START 2; P.END 8
The pattern will wrap between the indexes 2
and 5
.
With wrap enabled, a pattern length of 10, a start location of 3, and an end location of 6.
P.WRAP 1; P.L 10; P.START 3; P.END 6
The pattern will wrap between the indexes 3
and 6
.
If wrap is disabled (P.WRAP 0
) a pattern will run between its start and end locations and halt at either bound.
This applies to PN.WRAP
as well, except the pattern number is the first variable and a second variable specifies the wrap behavior (0/1
).
P.I
P.I
/P.I x
get/set index position for the working pattern. all values greater than pattern length return the first step beyond the pattern length. negative values are indexed backwards from the end of the pattern length.
Example:
With a pattern length of 6
(P.L 6
), yielding an index range of 0-5
:
P.I 3
moves the index of the working pattern to 3
P.I 10
moves the index of the working pattern to 6
P.I -2
moves the index of the working pattern to 4
This applies to PN.I
, except the pattern number is the first variable and a second variable specifics the index.
Control flow
OP | OP (set) | (aliases) | Description |
---|---|---|---|
IF x: ... |
if x is not zero execute command |
||
ELIF x: ... |
if all previous IF / ELIF fail, and x is not zero, execute command |
||
ELSE: ... |
if all previous IF / ELIF fail, excute command |
||
L x y: ... |
run the command sequentially with I values from x to y |
||
W x: ... |
run the command while condition x is true | ||
EVERY x: ... |
run the command every x times the command is called |
||
SKIP x: ... |
run the command every time except the x th time. |
||
OTHER: ... |
runs the command when the previous EVERY /SKIP did not run its command. |
||
SYNC x |
synchronizes all EVERY and SKIP counters to offset x . |
||
PROB x: ... |
potentially execute command with probability x (0-100) |
||
SCRIPT |
SCRIPT x |
$ |
get current script number, or execute script x (1-8), recursion allowed |
SCENE |
SCENE x |
get the current scene number, or load scene x (0-31) |
|
KILL |
clears stack, clears delays, cancels pulses, cancels slews, disables metronome | ||
BREAK |
BRK |
halts execution of the current script | |
INIT |
clears all state data | ||
INIT.CV x |
clears all parameters on CV associated with output x | ||
INIT.CV.ALL |
clears all parameters on all CV’s | ||
INIT.DATA |
clears all data held in all variables | ||
INIT.P x |
clears pattern associated with pattern number x | ||
INIT.P.ALL |
clears all patterns | ||
INIT.SCENE |
loads a blank scene | ||
INIT.SCRIPT x |
clear script number x | ||
INIT.SCRIPT.ALL |
clear all scripts | ||
INIT.TIME x |
clear time on trigger x | ||
INIT.TR x |
clear all parameters on trigger associated with TR x | ||
INIT.TR.ALL |
clear all triggers |
IF
IF x: ...
If x
is not zero execute command
Advanced IF
/ ELIF
/ ELSE
usage
- Intermediate statements always run
```text
SCRIPT 1:
IF 0: 0 => do nothing
TR.P 1 => always happens
ELSE: TR.P 2 => else branch runs because of the previous IF
```
ELSE
without anIF
```text
SCRIPT 1:
ELSE: TR.P 1 => never runs, as there is no preceding IF
```
ELIF
without anIF
```text
SCRIPT 1:
ELIF 1: TR.P 1 => never runs, as there is no preceding IF
```
- Independent scripts
```text
SCRIPT 1:
IF 1: TR.P 1 => pulse output 1
SCRIPT 2:
ELSE: TR.P 2 => never runs regardless of what happens in script 1
(see example 2)
```
- Dependent scripts
```text
SCRIPT 1:
IF 0: TR.P 1 => do nothing
SCRIPT 2 => will pulse output 2
SCRIPT 2:
ELSE: TR.P 2 => will not pulse output 2 if called directly,
but will if called from script 1
```
L
L x y: ...
Run the command sequentially with I
values from x
to y
.
For example:
L 1 4: TR.PULSE I => pulse outputs 1, 2, 3 and 4
L 4 1: TR.PULSE I => pulse outputs 4, 3, 2 and 1
W
W x: ...
Runs the command while the condition x
is true or the loop iterations exceed 10000.
For example, to find the first iterated power of 2 greater than 100:
A 2
W LT A 100: A * A A
A will be 256.
EVERY
EVERY x: ...
Runs the command every x
times the line is executed. This is tracked on a per-line basis, so each script can have 6 different “dividers”.
Here is a 1-script clock divider:
EVERY 2: TR.P 1
EVERY 4: TR.P 2
EVERY 8: TR.P 3
EVERY 16: TR.P 4
The numbers do not need to be evenly divisible by each other, so there is no problem with:
EVERY 2: TR.P 1
EVERY 3: TR.P 2
SKIP
SKIP x: ...
This is the corollary function to EVERY
, essentially behaving as its exact opposite.
OTHER
OTHER: ...
OTHER
can be used to do somthing alternately with a preceding EVERY
or SKIP
command.
For example, here is a script that alternates between two triggers to make a four-on-the-floor beat with hats between the beats:
EVERY 4: TR.P 1
OTHER: TR.P 2
You could add snares on beats 2 and 4 with:
SKIP 2: TR.P 3
SYNC
SYNC x
Causes all of the EVERY
and SYNC
counters to synchronize their offsets, respecting their individual divisor values.
Negative numbers will synchronize to to the divisor value, such that SYNC -1
causes all every counters to be 1 number before their divisor, causing each EVERY
to be true on its next call, and each SKIP
to be false.
SCRIPT
SCRIPT
/SCRIPT x
- alias:
$
Execute script x
(1-8), recursion allowed.
There is a limit of 8 for the maximum number of nested calls to SCRIPT
to stop infinite loops from locking up the Teletype.
SCENE
SCENE
/SCENE x
Load scene x
(0-31).
Does not execute the I
script. Will not execute from the I
script on scene load. Will execute on subsequent calls to the I
script.
WARNING: You will lose any unsaved changes to your scene.
INIT
INIT
WARNING: You will lose all settings when you initialize using INIT
- there is NO undo!
INIT.DATA
INIT.DATA
Clears the following variables and resets them to default values: A, B, C, D, CV slew, Drunk min/max, M, O, Q, R, T, TR. Does not affect the CV input (IN) or the Parameter knob (PARAM) values.
Maths
Logical operators such as EQ
, OR
and LT
return 1
for true, and 0
for false.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
ADD x y |
+ |
add x and y together |
|
SUB x y |
- |
subtract y from x |
|
MUL x y |
* |
multiply x and y together |
|
DIV x y |
/ |
divide x by y |
|
MOD x y |
% |
find the remainder after division of x by y |
|
RAND x |
RND |
generate a random number between 0 and x inclusive |
|
RRAND x y |
RRND |
generate a random number between x and y inclusive |
|
TOSS |
randomly return 0 or 1 |
||
? x y z |
if condition x is true return y , otherwise return z |
||
MIN x y |
return the minimum of x and y |
||
MAX x y |
return the maximum of x and y |
||
LIM x y z |
limit the value x to the range y to z inclusive |
||
WRAP x y z |
WRP |
limit the value x to the range y to z inclusive, but with wrapping |
|
QT x y |
round x to the closest multiple of y (quantise) |
||
AVG x y |
the average of x and y |
||
EQ x y |
== |
does x equal y |
|
NE x y |
!= , XOR |
x is not equal to y |
|
LT x y |
< |
x is less than y |
|
GT x y |
> |
x is greater than y |
|
LTE x y |
<= |
x is less than or equal to y |
|
GTE x y |
>= |
x is greater than or equal to y |
|
EZ x |
! |
x is 0 , equivalent to logical NOT |
|
NZ x |
x is not 0 |
||
LSH x y |
<< |
left shift x by y bits, in effect multiply x by 2 to the power of y |
|
RSH x y |
>> |
right shift x by y bits, in effect divide x by 2 to the power of y |
|
| x y |
bitwise or x |
||
& x y |
bitwise and x & y |
||
^ x y |
bitwise xor x ^ y |
||
~ x |
bitwise not, i.e.: inversion of x |
||
BSET x y |
set bit y in value x |
||
BGET x y |
get bit y in value x |
||
BCLR x y |
clear bit y in value x |
||
ABS x |
absolute value of x |
||
AND x y |
&& |
logical AND of x and y |
|
OR x y |
|| |
logical OR of x and y |
|
JI x y |
just intonation helper, precision ratio divider normalised to 1V | ||
SCALE a b x y i |
SCL |
scale i from range a to b to range x to y , i.e. i * (y - x) / (b - a) |
|
ER f l i |
Euclidean rhythm, f is fill (1-32 ), l is length (1-32 ) and i is step (any value), returns 0 or 1 |
||
BPM x |
milliseconds per beat in BPM x |
||
N x |
converts an equal temperament note number to a value usable by the CV outputs (x in the range -127 to 127 ) |
||
V x |
converts a voltage to a value usable by the CV outputs (x between 0 and 10 ) |
||
VV x |
converts a voltage to a value usable by the CV outputs (x between 0 and 1000 , 100 represents 1V) |
||
EXP x |
exponentiation table lookup. 0-16383 range (V 0-10 ) |
||
CHAOS x |
get next value from chaos generator, or set the current value | ||
CHAOS.R x |
get or set the R parameter for the CHAOS generator |
||
CHAOS.ALG x |
get or set the algorithm for the CHAOS generator. 0 = LOGISTIC, 1 = CUBIC, 2 = HENON, 3 = CELLULAR |
||
R |
generate a random number | ||
R.MIN x |
set the lower end of the range from 0 – 32767 | ||
R.MAX x |
set the upper end of the range from 0 – 32767 |
MUL
MUL x y
- alias:
*
returns x
times y
, bounded to integer limits
AND
AND x y
- alias:
&&
Logical AND of x
and y
. Returns 1
if both x
and y
are greater than 0
, otherwise it returns 0
.
OR
OR x y
- alias:
||
Logical OR of x
and y
. Returns 1
if either x
or y
are greater than 0
, otherwise it returns 0
.
ER
ER f l i
Euclidean rhythm helper, as described by Godfried Toussaint in his 2005 paper “The Euclidean Algorithm Generates Traditional Musical Rhythms”1. From the abstract:
f
is fill (1-32
) and should be less then or equal to lengthl
is length (1-32
)i
is the step index, and will work with negative as well as positive numbers
If you wish to add rotation as well, use the following form:
ER f l SUB i r
where r
is the number of step of forward rotation you want.
For more info, see the post on samdoshi.com
N
N x
The N
OP converts an equal temperament note number to a value usable by the CV outputs.
Examples:
CV 1 N 60 => set CV 1 to middle C, i.e. 5V
CV 1 N RAND 24 => set CV 1 to a random note from the lowest 2 octaves
Metronome
An internal metronome executes the M script at a specified rate (in ms). By default the metronome is enabled (M.ACT 1
) and set to 1000ms (M 1000
). The metro can be set as fast as 25ms (M 25
). An additional M!
op allows for setting the metronome to experimental rates as high as 2ms (M! 2
). WARNING: when using a large number of i2c commands in the M script at metro speeds beyond the 25ms teletype stability issues can occur.
Access the M script directly with alt-<F10>
or run the script once using <F10>
.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
M |
M x |
get/set metronome interval to x (in ms), default 1000 , minimum value 25 |
|
M! |
M! x |
get/set metronome to experimental interval x (in ms), minimum value 2 |
|
M.ACT |
M.ACT x |
get/set metronome activation to x (0/1 ), default 1 (enabled) |
|
M.RESET |
hard reset metronome count without triggering |
Delay
The DEL
delay op allow commands to be sheduled for execution after a defined interval by placing them into a buffer which can hold up to 8 commands. Commands can be delayed by up to 16 seconds
In LIVE mode, the second icon (an upside-down U) will be lit up when there is a command in the DEL
buffer.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
DEL x: ... |
Delay command by x ms |
||
DEL.CLR |
Clear the delay buffer |
DEL
DEL x: ...
Delay the command following the colon by x
ms by placing it into a buffer. The buffer can hold up to 8 commands. If the buffer is full, additional commands will be discarded.
DEL.CLR
DEL.CLR
Clear the delay buffer, cancelling the pending commands.
Stack
These operators manage a last in, first out, stack of commands, allowing them to be memorised for later execution at an unspecified time. The stack can hold up to 8 commands. Commands added to a full stack will be discarded.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
S: ... |
Place a command onto the stack | ||
S.CLR |
Clear all entries in the stack | ||
S.ALL |
Execute all entries in the stack | ||
S.POP |
Execute the most recent entry | ||
S.L |
Get the length of the stack |
S
S: ...
Add the command following the colon to the top of the stack. If the stack is full, the command will be discarded.
S.CLR
S.CLR
Clear the stack, cancelling all of the commands.
S.ALL
S.ALL
Execute all entries in the stack (last in, first out), clearing the stack in the process.
S.POP
S.POP
Pop the most recent command off the stack and execute it.
S.L
S.L
Get the number of entries in the stack.
Queue
These operators manage a first in, first out, queue of values. The queue can hold up to 16 values. The length of the queue can be dynamically changed and the contents will be preserved. There is also an averaging operator which is useful for smoothing input values.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
Q |
Q x |
Modify the queue entries | |
Q.N |
Q.N x |
The queue length | |
Q.AVG |
Q.AVG x |
Return the average of the queue |
Q
Q
/Q x
Gets the output value from the queue, or places x
into the queue.
Q.N
Q.N
/Q.N x
Gets/sets the length of the queue.
Q.AVG
Q.AVG
/Q.AVG x
Getting the value the average of the values in the queue. Setting x
sets the value of each entry in the queue to x
.
Turtle
A 2-dimensional, movable index into the pattern values as displayed on the TRACKER screen.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
@ |
@ x |
get or set the current pattern value under the turtle | |
@X |
@X x |
get the turtle X coordinate, or set it to x | |
@Y |
@Y x |
get the turtle Y coordinate, or set it to x | |
@MOVE x y |
move the turtle x cells in the X axis and y cells in the Y axis | ||
@F x1 y1 x2 y2 |
set the turtle’s fence to corners x1,y1 and x2,y2 | ||
@FX1 |
@FX1 x |
get the left fence line or set it to x | |
@FX2 |
@FX2 x |
get the right fence line or set it to x | |
@FY1 |
@FY1 x |
get the top fence line or set it to x | |
@FY2 |
@FY2 x |
get the bottom fence line or set it to x | |
@SPEED |
@SPEED x |
get the speed of the turtle’s @STEP in cells per step or set it to x | |
@DIR |
@DIR x |
get the direction of the turtle’s @STEP in degrees or set it to x | |
@STEP |
move @SPEED /100 cells forward in @DIR , triggering @SCRIPT on cell change |
||
@BUMP |
@BUMP 1 |
get whether the turtle fence mode is BUMP, or set it to BUMP with 1 | |
@WRAP |
@WRAP 1 |
get whether the turtle fence mode is WRAP, or set it to WRAP with 1 | |
@BOUNCE |
@BOUNCE 1 |
get whether the turtle fence mode is BOUNCE, or set it to BOUNCE with 1 | |
@SCRIPT |
@SCRIPT x |
get which script runs when the turtle changes cells, or set it to x | |
@SHOW |
@SHOW 0/1 |
get whether the turtle is displayed on the TRACKER screen, or turn it on or off |
Grid
Grid operators allow creating scenes that can interact with grid connected to teletype (important: grid must be powered externally, do not connect it directly to teletype!). You can light up individual LEDs, draw shapes and create controls (such as buttons and faders) that can be used to trigger and control scripts. You can take advantage of grid operators even without an actual grid by using the built in Grid Visualizer.
For more information on grid integration see Advanced section and Grid Studies.
As there are many operators let’s review some naming conventions that apply to the majority of them. All grid ops start with G.
. For control related ops this is followed by 3 letters specifying the control: G.BTN
for buttons, G.FDR
for faders. To define a control you use the main ops G.BTN
and G.FDR
. To define multiple controls replace the last letter with X
: G.BTX
, G.FDX
.
All ops that initialize controls use the same list of parameters: id, coordinates, width, height, type, level, script. When creating multiple controls there are two extra parameters: the number of columns and the number of rows. Controls are created in the current group (set with G.GRP
). To specify a different group use the group versions of the 4 above ops - G.GBT
, G.GFD
, G.GBX
, G.GFX
and specify the desired group as the first parameter.
All controls share some common properties, referenced by adding a .
and:
EN
:G.BTN.EN
,G.FDR.EN
- enables or disables a controlV
:G.BTN.V
,G.FDR.V
- value, 1/0 for buttons, range value for fadersL
:G.BTN.L
,G.FDR.L
- level (brightness level for buttons and coarse faders, max value level for fine faders)X
:G.BTN.X
,G.FDR.X
- the X coordinateY
:G.BTN.Y
,G.FDR.Y
- the Y coordinate
To get/set properties for individual controls you normally specify the control id as the first parameter: G.FDR.V 5
will return the value of fader 5. Quite often the actual id is not important, you just want to work with the latest control pressed. As these are likely the ops to be used most often they are offered as shortcuts without a .
: G.BTNV
returns the value of the last button pressed, G.FDRL 4
will set the level of the last fader pressed etc etc.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
G.RST |
full grid reset | ||
G.CLR |
clear all LEDs | ||
G.DIM level |
set dim level | ||
G.ROTATE x |
set grid rotation | ||
G.KEY x y action |
emulate grid press | ||
G.GRP |
G.GRP id |
get/set current group | |
G.GRP.EN id |
G.GRP.EN id x |
enable/disable group or check if enabled | |
G.GRP.RST id |
reset all group controls | ||
G.GRP.SW id |
switch groups | ||
G.GRP.SC id |
G.GRP.SC id script |
get/set group script | |
G.GRPI |
get last group | ||
G.LED x y |
G.LED x y level |
get/set LED | |
G.LED.C x y |
clear LED | ||
G.REC x y w h fill border |
draw rectangle | ||
G.RCT x1 y1 x2 y2 fill border |
draw rectangle | ||
G.BTN id x y w h type level script |
initialize button | ||
G.GBT group id x y w h type level script |
initialize button in group | ||
G.BTX id x y w h type level script columns rows |
initialize multiple buttons | ||
G.GBX group id x y w h type level script columns rows |
initialize multiple buttons in group | ||
G.BTN.EN id |
G.BTN.EN id x |
enable/disable button or check if enabled | |
G.BTN.X id |
G.BTN.X id x |
get/set button x coordinate | |
G.BTN.Y id |
G.BTN.Y id y |
get/set button y coordinate | |
G.BTN.V id |
G.BTN.V id value |
get/set button value | |
G.BTN.L id |
G.BTN.L id level |
get/set button level | |
G.BTNI |
id of last pressed button | ||
G.BTNX |
G.BTNX x |
get/set x of last pressed button | |
G.BTNY |
G.BTNY y |
get/set y of last pressed button | |
G.BTNV |
G.BTNV value |
get/set value of last pressed button | |
G.BTNL |
G.BTNL level |
get/set level of last pressed button | |
G.BTN.SW id |
switch button | ||
G.BTN.PR id action |
emulate button press/release | ||
G.GBTN.V group value |
set value for group buttons | ||
G.GBTN.L group odd_level even_level |
set level for group buttons | ||
G.GBTN.C group |
get count of currently pressed | ||
G.GBTN.I group index |
get id of pressed button | ||
G.GBTN.W group |
get button block width | ||
G.GBTN.H group |
get button block height | ||
G.GBTN.X1 group |
get leftmost pressed x | ||
G.GBTN.X2 group |
get rightmost pressed x | ||
G.GBTN.Y1 group |
get highest pressed y | ||
G.GBTN.Y2 group |
get lowest pressed y | ||
G.FDR id x y w h type level script |
initialize fader | ||
G.GFD grp id x y w h type level script |
initialize fader in group | ||
G.FDX id x y w h type level script columns rows |
initialize multiple faders | ||
G.GFX group id x y w h type level script columns rows |
initialize multiple faders in group | ||
G.FDR.EN id |
G.FDR.EN id x |
enable/disable fader or check if enabled | |
G.FDR.X id |
G.FDR.X id x |
get/set fader x coordinate | |
G.FDR.Y id |
G.FDR.Y id y |
get/set fader y coordinate | |
G.FDR.N id |
G.FDR.N id value |
get/set fader value | |
G.FDR.V id |
G.FDR.V id value |
get/set scaled fader value | |
G.FDR.L id |
G.FDR.L id level |
get/set fader level | |
G.FDRI |
id of last pressed fader | ||
G.FDRX |
G.FDRX x |
get/set x of last pressed fader | |
G.FDRY |
G.FDRY y |
get/set y of last pressed fader | |
G.FDRN |
G.FDRN value |
get/set value of last pressed fader | |
G.FDRV |
G.FDRV value |
get/set scaled value of last pressed fader | |
G.FDRL |
G.FDRL level |
get/set level of last pressed fader | |
G.FDR.PR id value |
emulate fader press | ||
G.GFDR.N group value |
set value for group faders | ||
G.GFDR.V group value |
set scaled value for group faders | ||
G.GFDR.L group odd_level even_level |
set level for group faders | ||
G.GFDR.RN group min max |
set range for group faders |
G.RST
G.RST
Full grid reset - hide all controls and reset their properties to the default values, clear all LEDs, reset the dim level and the grid rotation.
G.CLR
G.CLR
Clear all LEDs set with G.LED
, G.REC
or G.RCT
.
G.DIM
G.DIM level
Set the dim level (0..14, higher values dim more). To remove set to 0.
G.ROTATE
G.ROTATE x
Set the grid rotation (0 - no rotation, 1 - rotate by 180 degrees).
G.KEY
G.KEY x y action
Emulate a grid key press at the specified coordinates (0-based). Set action
to 1 to emulate a press, 0 to emulate a release. You can also emulate a button press with G.BTN.PR
and a fader press with G.FDR.PR
.
G.GRP
G.GRP
/G.GRP id
Get or set the current group. Grid controls created without specifying a group will be assigned to the current group. This op doesn’t enable/disable groups - use G.GRP.EN
for that. The default current group is 0. 64 groups are available.
G.GRP.EN
G.GRP.EN id
/G.GRP.EN id x
Enable or disable the specified group or check if it’s currently enabled. 1 means enabled, 0 means disabled. Enabling or disabling a group enables / disables all controls assigned to that group (disabled controls are not shown and receive no input). This allows groups to be used as pages - initialize controls in different groups, and then simply enable one group at a time.
G.GRP.RST
G.GRP.RST id
Reset all controls associated with the specified group. This will disable the controls and reset their properties to the default values. This will also reset the fader scale range to 0..16383.
G.GRP.SW
G.GRP.SW id
Switch groups. Enables the specified group, disables all others.
G.GRP.SC
G.GRP.SC id
/G.GRP.SC id script
Assign a script to the specified group, or get the currently assigned script. The script gets executed whenever a control associated with the group receives input. It is possible to have different scripts assigned to a control and the group it belongs to. Use 9 for Metro and 10 for Init. To unassign, set it to 0.
G.GRPI
G.GRPI
Get the id of the last group that received input. This is useful when sharing a script between multiple groups.
G.LED
G.LED x y
/G.LED x y level
Set the LED level or get the current level at the specified coordinates. Possible level range is 0..15 (on non varibright grids anything below 8 is ‘off’, 8 or above is ‘on’).
Grid controls get rendered first, and LEDs are rendered last. This means you can use LEDs to accentuate certain areas of the UI. This also means that any LEDs that are set will block whatever is underneath them, even with the level of 0. In order to completely clear an LED set its level to -3. There are two other special values for brightness: -1 will dim, and -2 will brighten what’s underneath. They can be useful to highlight the current sequence step, for instance.
G.LED.C
G.LED.C x y
Clear the LED at the specified coordinates. This is the same as setting the brightness level to -3. To clear all LEDs use G.CLR
.
G.REC
G.REC x y w h fill border
Draw a rectangle with the specified width and height. x
and y
are the coordinates of the top left corner. Coordinates are 0-based, with the 0,0 point located at the top left corner of the grid. You can draw rectangles that are partially outside of the visible area, and they will be properly cropped.
fill
and border
specify the brightness levels for the inner area and the one-LED-wide border respectively, 0..15 range. You can use the three special brightness levels: -1 to dim, -2 to brighten and -3 for transparency (you could draw just a frame by setting fill
to -3, for instance).
To draw lines, set the width or the height to 1. In this case only border
brightness level is used.
G.RCT
G.RCT x1 y1 x2 y2 fill border
Same as G.REC
but instead of specifying the width and height you specify the coordinates of the top left corner and the bottom right corner.
G.BTN
G.BTN id x y w h type level script
Initializes and enables a button with the specified id. 256 buttons are available (ids are 0-based so the possible id range is 0..255. The button will be assigned to the current group (set with G.GRP
). Buttons can be reinitialized at any point.
x
and y
specify the coordinates of the top left corner, and w
and h
specify width and height respectively. type
determines whether the button is latching (1) or momentary (0). level
sets the “off” brightness level, possible rand is -3..15 (the brightness level for pressed buttons is fixed at 13).
script
specifies the script to be executed when the button is pressed or released (the latter only for momentary buttons). Use 9 for Metro and 10 for Init. Use 0 if you don’t need a script assigned.
G.GBT
G.GBT group id x y w h type level script
Initialize and enable a button. Same as G.BTN
but you can also choose which group to assign the button too.
G.BTX
G.BTX id x y w h type level script columns rows
Initialize and enable a block of buttons in the current group with the specified number of columns and rows . Ids are incremented sequentially by columns and then by rows.
G.GBX
G.GBX group id x y w h type level script columns rows
Initialize and enable a block of buttons. Same as G.BTX
but you can also choose which group to assign the buttons too.
G.BTN.EN
G.BTN.EN id
/G.BTN.EN id x
Enable (set x
to 1) or disable (set x
to 0) a button with the specified id, or check if it’s currently enabled. Disabling a button hides it and stops it from receiving input but keeps all the other properties (size/location etc) intact.
G.BTN.X
G.BTN.X id
/G.BTN.X id x
Get or set x
coordinate for the specified button’s top left corner.
G.BTN.Y
G.BTN.Y id
/G.BTN.Y id y
Get or set y
coordinate for the specified button’s top left corner.
G.BTN.V
G.BTN.V id
/G.BTN.V id value
Get or set the specified button’s value. For buttons the value of 1 means the button is pressed and 0 means it’s not. If there is a script assigned to the button it will not be triggered if you change the value - use G.BTN.PR
for that.
Button values don’t change when a button is disabled. Button values are stored with the scene (both to flash and to USB sticks).
G.BTN.L
G.BTN.L id
/G.BTN.L id level
Get or set the specified button’s brightness level (-3..15). Please note you can only set the level for unpressed buttons, the level for pressed buttons is fixed at 13.
G.BTNI
G.BTNI
Get the id of the last pressed button. This is useful when multiple buttons are assigned to the same script.
G.BTNX
G.BTNX
/G.BTNX x
Get or set x
coordinate of the last pressed button’s top left corner. This is the same as G.BTN.X G.BTNI
.
G.BTNY
G.BTNY
/G.BTNY y
Get or set y
coordinate of the last pressed button’s top left corner. This is the same as G.BTN.Y G.BTNI
.
G.BTNV
G.BTNV
/G.BTNV value
Get or set the value of the last pressed button. This is the same as G.BTN.V G.BTNI
. This op is especially useful with momentary buttons when you want to react to presses or releases only - just put IF EZ G.BTNV: BREAK
in the beginning of the assigned script (this will ignore releases, to ignore presses replace NZ
with EZ
).
G.BTNL
G.BTNL
/G.BTNL level
Get or set the brightness level of the last pressed button. This is the same as G.BTN.L G.BTNI
.
G.BTN.SW
G.BTN.SW id
Set the value of the specified button to 1 (pressed), set it to 0 (not pressed) for all other buttons within the same group (useful for creating radio buttons).
G.BTN.PR
G.BTN.PR id action
Emulate pressing/releasing the specified button. Set action
to 1
for press, 0
for release (action
is ignored for latching buttons).
G.GBTN.V
G.GBTN.V group value
Set the value for all buttons in the specified group.
G.GBTN.L
G.GBTN.L group odd_level even_level
Set the brightness level (0..15) for all buttons in the specified group. You can use different values for odd and even buttons (based on their index within the group, not their id) - this can be a good way to provide some visual guidance.
G.GBTN.C
G.GBTN.C group
Get the total count of all the buttons in the specified group that are currently pressed.
G.GBTN.I
G.GBTN.I group index
Get the id of a currently pressed button within the specified group by its index (0-based). The index should be between 0 and C-1 where C is the total count of all pressed buttons (you can get it using G.GBTN.C
).
G.GBTN.W
G.GBTN.W group
Get the width of the rectangle formed by pressed buttons within the specified group. This is basically the distance between the leftmost and the rightmost pressed buttons, inclusive. This op is useful for things like setting a loop’s length, for instance. To do so, check if there is more than one button pressed (using G.GBTN.C
) and if there is, use G.GBTN.W
to set the length.
G.GBTN.H
G.GBTN.H group
Get the height of the rectangle formed by pressed buttons within the specified group (see G.GBTN.W
for more details).
G.GBTN.X1
G.GBTN.X1 group
Get the X coordinate of the leftmost pressed button in the specified group. If no buttons are currently pressed it will return -1.
G.GBTN.X2
G.GBTN.X2 group
Get the X coordinate of the rightmost pressed button in the specified group. If no buttons are currently pressed it will return -1.
G.GBTN.Y1
G.GBTN.Y1 group
Get the Y coordinate of the highest pressed button in the specified group. If no buttons are currently pressed it will return -1.
G.GBTN.Y2
G.GBTN.Y2 group
Get the Y coordinate of the lowest pressed button in the specified group. If no buttons are currently pressed it will return -1.
G.FDR
G.FDR id x y w h type level script
Initializes and enables a fader with the specified id. 64 faders are available (ids are 0-based so the possible id range is 0..63). The fader will be assigned to the current group (set with G.GRP
). Faders can be reinitialized at any point.
x
and y
specify the coordinates of the top left corner, and w
and h
specify width and height respectively.
type
determines the fader type and orientation. Possible values are:
- 0 - coarse, horizontal bar
- 1 - coarse, vertical bar
- 2 - coarse, horizontal dot
- 3 - coarse, vertical dot
- 4 - fine, horizontal bar
- 5 - fine, vertical bar
- 6 - fine, horizontal dot
- 7 - fine, vertical dot
Coarse faders have the possible range of 0..N-1 where N is width for horizontal faders or height for vertical faders. Pressing anywhere within the fader area sets the fader value accordingly. Fine faders allow selecting a bigger range of values by mapping the range to the fader’s height or width and dedicating the edge buttons for incrementing/decrementing. Fine faders employ varibrightness to reflect the current value.
level
has a different meaning for coarse and fine faders. For coarse faders it selects the background brightness level (similar to buttons). For fine faders this is the maximum value level (the minimum level being 0). In order to show each value distinctly using varibright the maximum level possible is the number of available buttons multiplied by 16 minus 1 (since range is 0-based). Remember that 2 buttons are always reserved for increment/decrement. Using a larger number is allowed - it will be automatically adjusted to what’s possible.
script
specifies the script to be executed when the fader value is changed. Use 9 for Metro and 10 for Init. Use 0 if you don’t need a script assigned.
G.GFD
G.GFD grp id x y w h type level script
Initialize and enable a fader. Same as G.FDR
but you can also choose which group to assign the fader too.
G.FDX
G.FDX id x y w h type level script columns rows
Initialize and enable a block of faders with the specified number of columns and rows in the current group. Ids are incremented sequentially by columns and then by rows.
G.GFX
G.GFX group id x y w h type level script columns rows
Initialize and enable a block of faders. Same as G.FDX
but you can also choose which group to assign the faders too.
G.FDR.EN
G.FDR.EN id
/G.FDR.EN id x
Enable (set x
to 1) or disable (set x
to 0) a fader with the specified id, or check if it’s currently enabled. Disabling a fader hides it and stops it from receiving input but keeps all the other properties (size/location etc) intact.
G.FDR.X
G.FDR.X id
/G.FDR.X id x
Get or set x
coordinate for the specified fader’s top left corner.
G.FDR.Y
G.FDR.Y id
/G.FDR.Y id y
Get or set y
coordinate for the specified fader’s top left corner.
G.FDR.N
G.FDR.N id
/G.FDR.N id value
Get or set the specified fader’s value. The possible range for coarse faders is 0..N-1 where N is fader’s width (for horizontal faders) or height (for vertical faders). For fine faders the possible range is 0..N where N is the maximum level set when the fader was initialized (see G.FDR
for more details).
Sometimes it’s more convenient to map the possible fader range to a different range (when using it to control a CV, for instance). Use G.FDR.V
for that.
If there is a script assigned to the fader it will not be triggered if you change the value - use G.FDR.PR
for that.
Fader values don’t change when a fader is disabled. Fader values are stored with the scene (both to flash and to USB sticks).
G.FDR.V
G.FDR.V id
/G.FDR.V id value
Get or set the specified fader’s value mapped to a range set with G.GFDR.RN
. This op is very convenient for using faders to control a known range, such as CV - simply create a fader and set a range and then assign values directly without any additional calculations, like this: CV 1 G.FDR.V 1
.
G.FDR.L
G.FDR.L id
/G.FDR.L id level
Get or set the specified fader’s brightness level (for coarse faders), or the maximum value level (for fine faders).
G.FDRI
G.FDRI
Get the id of the last pressed fader. This is useful when multiple faders are assigned to the same script.
G.FDRX
G.FDRX
/G.FDRX x
Get or set x
coordinate of the last pressed fader’s top left corner. This is the same as G.FDR.X G.FDRI
.
G.FDRY
G.FDRY
/G.FDRY y
Get or set y
coordinate of the last pressed fader’s top left corner. This is the same as G.BTN.Y G.BTNI
.
G.FDRN
G.FDRN
/G.FDRN value
Get or set the value of the last pressed fader. This is the same as G.FDR.N G.FDRI
. See G.FDR.N
for more details.
G.FDRV
G.FDRV
/G.FDRV value
Get or set the scaled value of the last pressed fader. This is the same as G.FDR.V G.FDRI
. See G.FDR.V
for more details.
G.FDRL
G.FDRL
/G.FDRL level
Get or set the brightness level (for coarse faders), or the maximum value level (for fine faders) of the last pressed fader. This is the same as G.FDR.L G.BTNI
. For more details on levels see G.FDR
.
G.FDR.PR
G.FDR.PR id value
Emulate pressing the specified fader. Fader value will be set to the specified value, and if there is a script assigned it will be executed.
G.GFDR.N
G.GFDR.N group value
Set the value for all faders in the specified group. This can be useful for resetting all faders in a group. See G.FDR.N
for more details.
G.GFDR.V
G.GFDR.V group value
Set the scaled value for all faders in the specified group. This can be useful for resetting all faders in a group. See G.FDR.V
for more details.
G.GFDR.L
G.GFDR.L group odd_level even_level
Set the brightness level (0..15) for all faders in the specified group. You can use different values for odd and even faders (based on their index within the group, not their id) - this can be a good way to provide some visual guidance.
G.GFDR.RN
G.GFDR.RN group min max
Set the range to be used for V
fader values (G.FDR.V
, G.FDRV
, G.GFDR.V
). While the .N
ops provide the actual fader value sometimes it’s more convenient to map it to a different range so it can be used directly for something like a CV without having to scale it each time.
An example: let’s say you create a coarse fader with the width of 8 which will be used to control a CV output where the voltage must be in the 2V..5V range. Using G.FDR.N
you would need to do this: CV 1 SCL 0 7 V 2 V 5 G.FDR.N 0
. Instead you can set the range for scaling once: G.GFDR.RN 0 V 2 V 5
(assuming the fader is in group 0) and then simply do CV 1 G.FDR.V 0
.
The range is shared by all faders within the same group. If you need to use a different range use a different group when initializing a fader.
The default range is 0..16383. G.RST
and G.GRP.RST
reset ranges to the default value.
Ansible
OP | OP (set) | (aliases) | Description |
---|---|---|---|
KR.PRE |
KR.PRE x |
return current preset / load preset x |
|
KR.PERIOD |
KR.PERIOD x |
get/set internal clock period | |
KR.PAT |
KR.PAT x |
get/set current pattern | |
KR.SCALE |
KR.SCALE x |
get/set current scale | |
KR.POS x y |
KR.POS x y z |
get/set position z for track z , parameter y |
|
KR.L.ST x y |
KR.L.ST x y z |
get loop start for track x , parameter y / set to z |
|
KR.L.LEN x y |
KR.L.LEN x y z |
get length of track x , parameter y / set to z |
|
KR.RES x y |
reset position to loop start for track x , parameter y |
||
KR.CV x |
get the current CV value for channel x |
||
KR.MUTE x |
KR.MUTE x y |
get/set mute state for channel x (1 = muted, 0 = unmuted) |
|
KR.TMUTE x |
toggle mute state for channel x |
||
KR.CLK x |
advance the clock for channel x (channel must have teletype clocking enabled) |
||
ME.PRE |
ME.PRE x |
return current preset / load preset x |
|
ME.SCALE |
ME.SCALE x |
get/set current scale | |
ME.PERIOD |
ME.PERIOD x |
get/set internal clock period | |
ME.STOP x |
stop channel x (0 = all) |
||
ME.RES x |
reset channel x (0 = all), also used as “start” |
||
ME.CV x |
get the current CV value for channel x |
||
LV.PRE |
LV.PRE x |
return current preset / load preset x |
|
LV.RES x |
reset, 0 for soft reset (on next ext. clock), 1 for hard reset |
||
LV.POS |
LV.POS x |
get/set current position | |
LV.L.ST |
LV.L.ST x |
get/set loop start | |
LV.L.LEN |
LV.L.LEN x |
get/set loop length | |
LV.L.DIR |
LV.L.DIR x |
get/set loop direction | |
LV.CV x |
get the current CV value for channel x |
||
CY.PRE |
CY.PRE x |
return current preset / load preset x |
|
CY.RES x |
reset channel x (0 = all) |
||
CY.POS x |
CY.POS x y |
get / set position of channel x (x = 0 to set all), position between 0-255 |
|
CY.REV x |
reverse channel x (0 = all) |
||
CY.CV x |
get the current CV value for channel x |
||
MID.SLEW t |
set pitch slew time in ms (applies to all allocation styles except FIXED) | ||
MID.SHIFT o |
shift pitch CV by standard Teletype pitch value (e.g. N 6 , V -1 , etc) |
||
ARP.HLD h |
0 disables key hold mode, other values enable |
||
ARP.STY y |
set base arp style [0-7] | ||
ARP.GT v g |
set voice gate length [0-127], scaled/synced to course divisions of voice clock | ||
ARP.SLEW v t |
set voice slew time in ms | ||
ARP.RPT v n s |
set voice pattern repeat, n times [0-8], shifted by s semitones [-24, 24] |
||
ARP.DIV v d |
set voice clock divisor (euclidean length), range [1-32] | ||
ARP.FIL v f |
set voice euclidean fill, use 1 for straight clock division, range [1-32] | ||
ARP.ROT v r |
set voice euclidean rotation, range [-32, 32] | ||
ARP.ER v f d r |
set all euclidean rhythm | ||
ARP.RES v |
reset voice clock/pattern on next base clock tick | ||
ARP.SHIFT v o |
shift voice cv by standard tt pitch value (e.g. N 6, V -1, etc) |
KR.POS
KR.POS x y
/KR.POS x y z
Set position to z
for track x
, parameter y
.
A value of 0
for x
means all tracks.
A value of 0
for y
means all parameters
Parameters:
0
= all1
= trigger2
= note3
= octave4
= length
White Whale
OP | OP (set) | (aliases) | Description |
---|---|---|---|
WW.PRESET x |
Recall preset (0-7) | ||
WW.POS x |
Cut to position (0-15) | ||
WW.SYNC x |
Cut to position (0-15) and hard-sync the clock (if clocked internally) | ||
WW.START x |
Set the loop start position (0-15) | ||
WW.END x |
Set the loop end position (0-15) | ||
WW.PMODE x |
Set the loop play mode (0-5) | ||
WW.PATTERN x |
Change pattern (0-15) | ||
WW.QPATTERN x |
Change pattern (0-15) after current pattern ends | ||
WW.MUTE1 x |
Mute trigger 1 (0 = on, 1 = mute) | ||
WW.MUTE2 x |
Mute trigger 2 (0 = on, 1 = mute) | ||
WW.MUTE3 x |
Mute trigger 3 (0 = on, 1 = mute) | ||
WW.MUTE4 x |
Mute trigger 4 (0 = on, 1 = mute) | ||
WW.MUTEA x |
Mute CV A (0 = on, 1 = mute) | ||
WW.MUTEB x |
Mute CV B (0 = on, 1 = mute) |
WW.PRESET
WW.PRESET x
Set White Whale to preset x
(0-7). This takes effect immediately. The current playback position is not changed.
WW.POS
WW.POS x
Cut immediately to position (0-15) in the currently playing pattern.
WW.SYNC
WW.SYNC x
Cut to position (0-15) in the currently playing pattern. If White Whale is being clocked internaly, this also hard-syncs the clock.
WW.START
WW.START x
Set the loop start position (0-15). This does not impact the current playback position. If the playback position is outside of the defined loop it will continue to step until it enters the loop. If the start position is after the end position, the loop will wrap around the ends of the grid.
WW.END
WW.END x
Set the loop end position (0-15). This does not impact the current playback position. If the playback position is outside of the defined loop it will continue to step until it enters the loop. If the end position is before the end position, the loop will wrap around the ends of the grid.
WW.PMODE
WW.PMODE x
Set the loop play mode. The available modes are: 0 - forward, 1 - reverse, 2 - drunk, 3 - random, 4 - pingpong, 5 - pingpong with repeated end points.
WW.PATTERN
WW.PATTERN x
Change pattern. This does not impact the current playback position.
WW.QPATTERN
WW.QPATTERN x
Change pattern (0-15) after current pattern ends
WW.MUTE1
WW.MUTE1 x
Mute trigger 1 (0 = on, 1 = mute).
WW.MUTE2
WW.MUTE2 x
Mute trigger 2 (0 = on, 1 = mute).
WW.MUTE3
WW.MUTE3 x
Mute trigger 3 (0 = on, 1 = mute).
WW.MUTE4
WW.MUTE4 x
Mute trigger 4 (0 = on, 1 = mute).
WW.MUTEA
WW.MUTEA x
Mute CV A (0 = on, 1 = mute).
WW.MUTEB
WW.MUTEB x
Mute CV B (0 = on, 1 = mute).
Meadowphysics
For use on the original Meadowphysics module with version 2 firmware. Reference the Ansible ops for using Meadowphysics on the Ansible module.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
MP.PRESET x |
set Meadowphysics to preset x (indexed from 0 ) |
||
MP.RESET x |
reset countdown for channel x (0 = all, 1-8 = individual channels) |
||
MP.STOP x |
reset channel x (0 = all, 1-8 = individual channels) |
Earthsea
OP | OP (set) | (aliases) | Description |
---|---|---|---|
ES.PRESET x |
Recall preset x (0-7) |
||
ES.MODE x |
Set pattern clock mode. (0=normal, 1=II clock) | ||
ES.CLOCK x |
If II clocked, next pattern event | ||
ES.RESET x |
Reset pattern to start (and start playing) | ||
ES.PATTERN x |
Select playing pattern (0-15) | ||
ES.TRANS x |
Transpose the current pattern | ||
ES.STOP x |
Stop pattern playback. | ||
ES.TRIPLE x |
Recall triple shape (1-4) | ||
ES.MAGIC x |
Magic shape (1= halfspeed, 2=doublespeed, 3=linearize) |
ES.PRESET
ES.PRESET x
Recall the preset in location x
. This will stop the currently playing pattern.
ES.MODE
ES.MODE x
Sets the pattern clock mode. Setting x
to 0 sets Earthsea to use it’s internal clock. Setting x
to 1 clocks Earthsea via the ES.CLOCK
command.
ES.CLOCK
ES.CLOCK x
If Earthsea is II clocked (see ES.MODE
), and x
is non-zero, advance to the next pattern event.
ES.RESET
ES.RESET x
If x
is non-zero, reset the position in the current pattern to the start and start playing.
ES.PATTERN
ES.PATTERN x
Select pattern (0-15) from the current preset.
ES.TRANS
ES.TRANS x
Apply a transposition relative to the current ‘root’ position. Integer divisions of x
shift the root note up or down a row, x
modulo 5 will shift the position left or right up to 4 notes.
ES.STOP
ES.STOP x
If x
is non-zero, stop pattern playback, or stop record if currently recording.
ES.TRIPLE
ES.TRIPLE x
Recall triple shape (1-4).
ES.MAGIC
ES.MAGIC x
Apply one of the magic shapes, (1= halfspeed, 2=doublespeed, 3=linearize). Other shapes are not currently available via II ops.
Orca
Remote commands for Orca (alternative WW firmware). For detailed info and tips on usage please refer to the Orca manual.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
OR.CLK x |
Advance track x (1-4 ) |
||
OR.RST x |
Reset track x (1-4 ) |
||
OR.GRST x |
Global reset (x can be any value) |
||
OR.TRK x |
Choose track x (1-4 ) to be used by OR.DIV , OR.PHASE , OR.WGT or OR.MUTE |
||
OR.DIV x |
Set divisor for selected track to x (1-16 ) |
||
OR.PHASE x |
Set phase for selected track to x (0-16 ) |
||
OR.WGT x |
Set weight for selected track to x (1-8 ) |
||
OR.MUTE x |
Mute trigger selected by OR.TRK (0 = on, 1 = mute) |
||
OR.SCALE x |
Select scale x (1-16 ) |
||
OR.BANK x |
Select preset bank x (1-8 ) |
||
OR.PRESET x |
Select preset x (1-8 ) |
||
OR.RELOAD x |
Reload preset or bank (0 - current preset, 1 - current bank, 2 - all banks) |
||
OR.ROTS x |
Rotate scales by x (1-15 ) |
||
OR.ROTW x |
Rotate weights by x (1-3 ) |
||
OR.CVA x |
Select tracks for CV A where x is a binary number representing the tracks |
||
OR.CVB x |
Select tracks for CV B where x is a binary number representing the tracks |
OR.CLK
OR.CLK x
Gives you the ability to clock individual tracks. The master clock will still advance all 4 tracks.
OR.SCALE
OR.SCALE x
Value of 1-16
will select scale for both CV A and CV B. To select individual scales append their numbers, for instance, 105
will select scale 1 for CV A and scale 5 for CV B, and 1005
will select scale 10 for CV A and scale 5 for CV B.
OR.RELOAD
OR.RELOAD x
Abandons any unsaved changes and reloads selected presets/banks from flash. Could be useful in I
script.
OR.ROTS
OR.ROTS x
Rotates scales up. To rotate them down set x
to 16
minus the amount.
OR.ROTW
OR.ROTW x
Rotates weights up. To rotate them down set x
to 4
minus the amount.
OR.CVA
OR.CVA x
Convert a binary number representing selected tracks (so 1001
will select tracks 1 and 4, for instance) and set x
to that.
OR.CVB
OR.CVB x
Convert a binary number representing selected tracks (so 1001
will select tracks 1 and 4, for instance) and set x
to that.
Just Friends
More extensively covered in the Just Friends Documentation.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
JF.TR x y |
Simulate a TRIGGER input. x is channel (0 = all) and y is state (0 or 1 ) |
||
JF.RMODE x |
Set the RUN state of Just Friends when no physical jack is present. (0 = run off, non-zero = run on) |
||
JF.RUN x |
Send a ‘voltage’ to the RUN input. Requires JF.RMODE 1 to have been executed, or a physical cable in JF’s input. Thus Just Friend’s RUN modes are accessible without needing a physical cable & control voltage to set the RUN parameter. use JF.RUN V x to set to x volts. The expected range is V -5 to V 5 |
||
JF.SHIFT x |
Shifts the transposition of Just Friends, regardless of speed setting. Shifting by V 1 doubles the frequency in sound, or doubles the rate in shape. x = pitch, use N x for semitones, or V y for octaves. |
||
JF.VTR x y |
Like JF.TR with added volume control. Velocity is scaled with volts, so try V 5 for an output trigger of 5 volts. Channels remember their latest velocity setting and apply it regardless of TRIGGER origin (digital or physical). x = channel, 0 sets all channels. y = velocity, amplitude of output in volts. eg JF.VTR 1 V 4 . |
||
JF.TUNE x y z |
Adjust the tuning ratios used by the INTONE control. x = channel, y = numerator (set the multiplier for the tuning ratio), z = denominator (set the divisor for the tuning ratio). |
||
JF.MODE x |
Set the current choice of standard functionality, or Just Type alternate modes. You’ll likely want to put JF.MODE x in your Teletype INIT scripts. x = nonzero activates alternative modes. 0 restores normal. |
||
JF.VOX x y z |
Create a note at the specified channel, of the defined pitch & velocity. All channels can be set simultaneously with a chan value of 0. x = channel, y = pitch relative to C3, z = velocity (like JF.VTR ). |
||
JF.NOTE x y |
Polyphonically allocated note sequencing. Works as JF.VOX with chan selected automatically. Free voices will be taken first. If all voices are busy, will steal from the voice which has been active the longest. x = pitch relative to C3, y = velocity. |
||
JF.GOD x |
Redefines C3 to align with the ‘God’ note. x = 0 sets A to 440, x = 1 sets A to 432. |
||
JF.TICK x |
Sets the underlying timebase of the Geode. x = clock. 0 resets the timebase to the start of measure. 1 to 48 shall be sent repetitively. The value representing ticks per measure. 49 to 255 sets beats-per-minute and resets the timebase to start of measure. |
||
JF.QT x |
When non-zero, all events are queued & delayed until the next quantize event occurs. Using values that don’t align with the division of rhythmic streams will cause irregular patterns to unfold. Set to 0 to deactivate quantization. x = division, 0 deactivates quantization, 1 to 32 sets the subdivision & activates quantization. |
TELEXi Teletype Input Expander
The TELEXi (or TXi) is an input expander that adds 4 IN jacks and 4 PARAM knobs to the Teletype. There are jumpers on the back so you can hook more than one TXi to your Teletype simultaneously.
Inputs added to the system by the TELEX modules are addressed sequentially: 1-4 are on your first module of any type, 5-8 are on the second, 9-12 on the third, and so on. A few of the commands reference the module by its unit number – but those are rare.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
TI.PARAM x |
TI.PRM |
reads the value of PARAM knob x ; default return range is from 0 to 16383; return range can be altered by the TI.PARAM.MAP command |
|
TI.PARAM.QT x |
TI.PRM.QT |
return the quantized value for PARAM knob x using the scale set by TI.PARAM.SCALE ; default return range is from 0 to 16383 |
|
TI.PARAM.N x |
TI.PRM.N |
return the quantized note number for PARAM knob x using the scale set by TI.PARAM.SCALE |
|
TI.PARAM.SCALE x |
TI.PRM.SCALE |
select scale # y for PARAM knob x ; scales listed in full description |
|
TI.PARAM.MAP x y z |
TI.PRM.MAP |
maps the PARAM values for input x across the range y - z (defaults 0-16383) |
|
TI.IN x |
reads the value of IN jack x ; default return range is from -16384 to 16383 - representing -10V to +10V; return range can be altered by the TI.IN.MAP command |
||
TI.IN.QT x |
return the quantized value for IN jack x using the scale set by TI.IN.SCALE ; default return range is from -16384 to 16383 - representing -10V to +10V |
||
TI.IN.N x |
return the quantized note number for IN jack x using the scale set by TI.IN.SCALE |
||
TI.IN.SCALE x |
select scale # y for IN jack x ; scales listed in full description |
||
TI.IN.MAP x y z |
maps the IN values for input jack x across the range y - z (default range is -16384 to 16383 - representing -10V to +10V) |
||
TI.PARAM.INIT x |
TI.PRM.INIT |
initializes PARAM knob x back to the default boot settings and behaviors; neutralizes mapping (but not calibration) |
|
TI.IN.INIT x |
initializes IN jack x back to the default boot settings and behaviors; neutralizes mapping (but not calibration) |
||
TI.INIT d |
initializes all of the PARAM and IN inputs for device number d (1-8) |
||
TI.PARAM.CALIB x y |
TI.PRM.CALIB |
calibrates the scaling for PARAM knob x ; y of 0 sets the bottom bound; y of 1 sets the top bound |
|
TI.IN.CALIB x y |
calibrates the scaling for IN jack x ; y of -1 sets the -10V point; y of 0 sets the 0V point; y of 1 sets the +10V point |
||
TI.STORE d |
stores the calibration data for TXi number d (1-8) to its internal flash memory |
||
TI.RESET d |
resets the calibration data for TXi number d (1-8) to its factory defaults (no calibration) |
TI.PARAM.SCALE
TI.PARAM.SCALE x
- alias:
TI.PRM.SCALE
Quantization Scales
- Equal Temperament [DEFAULT]
- 12-tone Pythagorean scale
- Vallotti & Young scale (Vallotti version) also known as Tartini-Vallotti (1754)
- Andreas Werckmeister’s temperament III (the most famous one, 1681)
- Wendy Carlos’ Alpha scale with perfect fifth divided in nine
- Wendy Carlos’ Beta scale with perfect fifth divided by eleven
- Wendy Carlos’ Gamma scale with third divided by eleven or fifth by twenty
- Carlos Harmonic & Ben Johnston’s scale of ‘Blues’ from Suite f.micr.piano (1977) & David Beardsley’s scale of ‘Science Friction’
- Carlos Super Just
- Kurzweil “Empirical Arabic”
- Kurzweil “Just with natural b7th”, is Sauveur Just with 7/4
- Kurzweil “Empirical Bali/Java Harmonic Pelog”
- Kurzweil “Empirical Bali/Java Slendro, Siam 7”
- Kurzweil “Empirical Tibetian Ceremonial”
- Harry Partch’s 43-tone pure scale
- Partch’s Indian Chromatic, Exposition of Monophony, 1933.
- Partch Greek scales from “Two Studies on Ancient Greek Scales” on black/white
TI.PARAM.MAP
TI.PARAM.MAP x y z
- alias:
TI.PRM.MAP
If you would like to have a PARAM
knob values over a specific range, you can offload the processing for this to the TXo by mapping the range of the potentiometer using the MAP
command. It works a lot like the MAP
operator, but does the heavy lifting on the TXi, saving you space in your code and cycles on your processor.
For instance, let’s have the first knob return a range from 0 to 100.
TI.PARAM.MAP 1 0 100
You can reset the mapping by either calling the map command with the default range or by using the INIT
command (TO.PARAM.INIT 1
).
TI.IN.SCALE
TI.IN.SCALE x
Quantization Scales
- Equal Temperament [DEFAULT]
- 12-tone Pythagorean scale
- Vallotti & Young scale (Vallotti version) also known as Tartini-Vallotti (1754)
- Andreas Werckmeister’s temperament III (the most famous one, 1681)
- Wendy Carlos’ Alpha scale with perfect fifth divided in nine
- Wendy Carlos’ Beta scale with perfect fifth divided by eleven
- Wendy Carlos’ Gamma scale with third divided by eleven or fifth by twenty
- Carlos Harmonic & Ben Johnston’s scale of ‘Blues’ from Suite f.micr.piano (1977) & David Beardsley’s scale of ‘Science Friction’
- Carlos Super Just
- Kurzweil “Empirical Arabic”
- Kurzweil “Just with natural b7th”, is Sauveur Just with 7/4
- Kurzweil “Empirical Bali/Java Harmonic Pelog”
- Kurzweil “Empirical Bali/Java Slendro, Siam 7”
- Kurzweil “Empirical Tibetian Ceremonial”
- Harry Partch’s 43-tone pure scale
- Partch’s Indian Chromatic, Exposition of Monophony, 1933.
- Partch Greek scales from “Two Studies on Ancient Greek Scales” on black/white
TI.PARAM.CALIB
TI.PARAM.CALIB x y
- alias:
TI.PRM.CALIB
You can calibrate your PARAM
knob by using this command. The steps for full calibration are as follows:
- Turn the PARAM knob
x
all the way to the left - Send the command ‘TI.PARAM.CALIBRATE x 0’
- Turn the PARAM knob
x
all the way to the right - Send the command ‘TI.PARAM.CALIBRATE x 1’
Don’t forget to call the TI.STORE
command to save your calibration between sessions.
TI.IN.CALIB
TI.IN.CALIB x y
You can calibrate your IN
jack to external voltages by using this command. The steps for full calibration are as follows:
- Send a
-10V
signal to the inputx
- Send the command ‘TI.IN.CALIBRATE x -1’
- Send a
0V
signal to the inputx
- Send the command ‘TI.IN.CALIBRATE x 0’
- Send a
10V
signal to the inputx
- Send the command ‘TI.IN.CALIBRATE x 1’
Don’t forget to call the TI.STORE
command to save your calibration between sessions.
TELEXo Teletype Output Expander
The TELEXo (or TXo) is an output expander that adds an additional 4 Trigger and 4 CV jacks to the Teletype. There are jumpers on the back so you can hook more than one TXo to your Teletype simultaneously.
Outputs added to the system by the TELEX modules are addressed sequentially: 1-4 are on your first module of any type, 5-8 are on the second, 9-12 on the third, and so on. A few of the commands reference the module by its unit number – but those are rare.
Unlike the Teletype’s equivalent operators, the TXo does not have get commands for its functions. This was intentional as these commands eat up processor and bus-space. While they may be added in the future, as of now you cannot poll the TXo for the current state of its various operators.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
TO.TR x y |
sets the TR value for output x to y (0/1) |
||
TO.TR.TOG x |
toggles the TR value for output x |
||
TO.TR.PULSE x |
TO.TR.P |
pulses the TR value for output x for the duration set by TO.TR.TIME/S/M |
|
TO.TR.PULSE.DIV x y |
TO.TR.P.DIV |
sets the clock division factor for TR output x to y |
|
TO.TR.PULSE.MUTE x y |
TO.TR.P.MUTE |
mutes or un-mutes TR output x ; y is 1 (mute) or 0 (un-mute) |
|
TO.TR.TIME x y |
sets the time for TR.PULSE on output n ; y in milliseconds |
||
TO.TR.TIME.S x y |
sets the time for TR.PULSE on output n ; y in seconds |
||
TO.TR.TIME.M x y |
sets the time for TR.PULSE on output n ; y in minutes |
||
TO.TR.WIDTH x y |
sets the time for TR.PULSE on output n based on the width of its current metronomic value; y in percentage (0-100) |
||
TO.TR.POL x y |
sets the polarity for TR output n |
||
TO.TR.M.ACT x y |
sets the active status for the independent metronome for output x to y (0 /1 ); default 0 (disabled) |
||
TO.TR.M x y |
sets the independent metronome interval for output x to y in milliseconds; default 1000 |
||
TO.TR.M.S x y |
sets the independent metronome interval for output x to y in seconds; default 1 |
||
TO.TR.M.M x y |
sets the independent metronome interval for output x to y in minutes |
||
TO.TR.M.BPM x y |
sets the independent metronome interval for output x to y in Beats Per Minute |
||
TO.TR.M.COUNT x y |
sets the number of repeats before deactivating for output x to y ; default 0 (infinity) |
||
TO.TR.M.MUL x y |
multiplies the M rate on TR output x by y ; y defaults to 1 - no multiplication |
||
TO.TR.M.SYNC x |
synchronizes the PULSE for metronome on TR output number x |
||
TO.M.ACT d y |
sets the active status for the 4 independent metronomes on device d (1-8) to y (0 /1 ); default 0 (disabled) |
||
TO.M d y |
sets the 4 independent metronome intervals for device d (1-8) to y in milliseconds; default 1000 |
||
TO.M.S d y |
sets the 4 independent metronome intervals for device d to y in seconds; default 1 |
||
TO.M.M d y |
sets the 4 independent metronome intervals for device d to y in minutes |
||
TO.M.BPM d y |
sets the 4 independent metronome intervals for device d to y in Beats Per Minute |
||
TO.M.COUNT d y |
sets the number of repeats before deactivating for the 4 metronomes on device d to y ; default 0 (infinity) |
||
TO.M.SYNC d |
synchronizes the 4 metronomes for device number d (1-8) |
||
TO.CV x |
CV target output x ; y values are bipolar (-16384 to +16383) and map to -10 to +10 |
||
TO.CV.SLEW x y |
set the slew amount for output x ; y in milliseconds |
||
TO.CV.SLEW.S x y |
set the slew amount for output x ; y in seconds |
||
TO.CV.SLEW.M x y |
set the slew amount for output x ; y in minutes |
||
TO.CV.SET x y |
set the CV for output x (ignoring SLEW ); y values are bipolar (-16384 to +16383) and map to -10 to +10 |
||
TO.CV.OFF x y |
set the CV offset for output x ; y values are added at the final stage |
||
TO.CV.QT x y |
CV target output x ; y is quantized to output’s current CV.SCALE |
||
TO.CV.QT.SET x y |
set the CV for output x (ignoring SLEW ); y is quantized to output’s current CV.SCALE |
||
TO.CV.N x y |
target the CV to note y for output x ; y is indexed in the output’s current CV.SCALE |
||
TO.CV.N.SET x y |
set the CV to note y for output x ; y is indexed in the output’s current CV.SCALE (ignoring SLEW ) |
||
TO.CV.SCALE x y |
select scale # y for CV output x ; scales listed in full description |
||
TO.CV.LOG x y |
translates the output for CV output x to logarithmic mode y ; y defaults to 0 (off); mode 1 is for 0-16384 (0V-10V), mode 2 is for 0-8192 (0V-5V), mode 3 is for 0-4096 (0V-2.5V), etc. |
||
TO.CV.CALIB x |
Locks the current offset (CV.OFF ) as a calibration offset and saves it to persist between power cycles for output x . |
||
TO.CV.RESET x |
Clears the calibration offset for output x . |
||
TO.OSC x y |
targets oscillation for CV output x to y with the portamento rate determined by the TO.OSC.SLEW value; y is 1v/oct translated from the standard range (1-16384); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.SET x y |
set oscillation for CV output x to y (ignores CV.OSC.SLEW ); y is 1v/oct translated from the standard range (1-16384); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.QT x y |
targets oscillation for CV output x to y with the portamento rate determined by the TO.OSC.SLEW value; y is 1v/oct translated from the standard range (1-16384) and quantized to current OSC.SCALE ; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.QT.SET x y |
set oscillation for CV output x to y (ignores CV.OSC.SLEW ); y is 1v/oct translated from the standard range (1-16384) and quantized to current OSC.SCALE ; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.N x y |
targets oscillation for CV output x to note y with the portamento rate determined by the TO.OSC.SLEW value; see quantization scale reference for y ; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.N.SET x y |
sets oscillation for CV output x to note y (ignores CV.OSC.SLEW ); see quantization scale reference for y ; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.FQ x y |
targets oscillation for CV output x to frequency y with the portamento rate determined by the TO.OSC.SLEW value; y is in Hz; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.FQ x y |
sets oscillation for CV output x to frequency y (ignores CV.OSC.SLEW ); y is in Hz; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.LFO x y |
targets oscillation for CV output x to LFO frequency y with the portamento rate determined by the TO.OSC.SLEW value; y is in mHz (millihertz: 10^-3 Hz); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.LFO.SET x y |
sets oscillation for CV output x to LFO frequency y (ignores CV.OSC.SLEW ); y is in mHz (millihertz: 10^-3 Hz); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.CYC x y |
targets the oscillator cycle length to y for CV output x with the portamento rate determined by the TO.OSC.SLEW value; y is in milliseconds |
||
TO.OSC.CYC.SET x y |
sets the oscillator cycle length to y for CV output x (ignores CV.OSC.SLEW ); y is in milliseconds |
||
TO.OSC.CYC.S x y |
targets the oscillator cycle length to y for CV output x with the portamento rate determined by the TO.OSC.SLEW value; y is in seconds |
||
TO.OSC.CYC.S.SET x y |
sets the oscillator cycle length to y for CV output x (ignores CV.OSC.SLEW ); y is in seconds |
||
TO.OSC.CYC.M x y |
targets the oscillator cycle length to y for CV output x with the portamento rate determined by the TO.OSC.SLEW value; y is in minutes |
||
TO.OSC.CYC.M.SET x y |
sets the oscillator cycle length to y for CV output x (ignores CV.OSC.SLEW ); y is in minutes |
||
TO.OSC.SCALE x y |
select scale # y for CV output x ; scales listed in full description |
||
TO.OSC.WAVE x y |
set the waveform for output x to y ; y values range 0-4999 ; values translate to sine (0), triangle (1000), saw (2000), pulse (3000), or noise (4000); oscillator shape between values is a blend of the pure waveforms |
||
TO.OSC.RECT x y |
rectifies the polarity of the oscillator for output x to y ; range for y is -2 to 2; default is 0 (no rectification); 1 & -1 are partial rectification - omitting all values on the other side of the sign; 2 & -2 are full rectification - inverting values from the other pole |
||
TO.OSC.WIDTH x y |
sets the width of the pulse wave on output x to y ; y is a percentage of total width (0 to 100); only affects waveform 3000 |
||
TO.OSC.SYNC x |
resets the phase of the oscillator on CV output x (relative to TO.OSC.PHASE ) |
||
TO.OSC.PHASE x y |
sets the phase offset of the oscillator on CV output x to y (0 to 16383); y is the range of one cycle |
||
TO.OSC.SLEW x y |
sets the frequency slew time (portamento) for the oscillator on CV output x to y ; y in milliseconds |
||
TO.OSC.SLEW.S x y |
sets the frequency slew time (portamento) for the oscillator on CV output x to y ; y in seconds |
||
TO.OSC.SLEW.M x y |
sets the frequency slew time (portamento) for the oscillator on CV output x to y ; y in minutes |
||
TO.OSC.CTR x y |
centers the oscillation on CV output x to y ; y values are bipolar (-16384 to +16383) and map to -10 to +10 |
||
TO.ENV.ACT x y |
activates/deactivates the AD envelope generator for the CV output x ; y turns the envelope generator off (0 - default) or on (1); CV amplitude is used as the peak for the envelope and needs to be > 0 for the envelope to be perceivable |
||
TO.ENV x y |
This parameter essentially allows output x to act as a gate between the 0 and 1 state. Changing this value from 0 to 1 causes the envelope to trigger the attack phase and hold at the peak CV value; changing this value from 1 to 0 causes the decay stage of the envelope to be triggered. |
||
TO.ENV.TRIG x |
triggers the envelope at CV output x to cycle; CV amplitude is used as the peak for the envelope and needs to be > 0 for the envelope to be perceivable |
||
TO.ENV.ATT x y |
set the envelope attack time to y for CV output x ; y in milliseconds (default 12 ms) |
||
TO.ENV.ATT.S x y |
set the envelope attack time to y for CV output x ; y in seconds |
||
TO.ENV.ATT.M x y |
set the envelope attack time to y for CV output x ; y in minutes |
||
TO.ENV.DEC x y |
set the envelope decay time to y for CV output x ; y in milliseconds (default 250 ms) |
||
TO.ENV.DEC.S x y |
set the envelope decay time to y for CV output x ; y in seconds |
||
TO.ENV.DEC.M x y |
set the envelope decay time to y for CV output x ; y in minutes |
||
TO.ENV.EOR x n |
fires a PULSE at the End of Rise to the unit-local trigger output ‘n’ for the envelope on CV output x ; n refers to trigger output 1-4 on the same TXo as CV output ‘y’ |
||
TO.ENV.EOC x n |
fires a PULSE at the End of Cycle to the unit-local trigger output ‘n’ for the envelope on CV output x ; n refers to trigger output 1-4 on the same TXo as CV output ‘y’ |
||
TO.ENV.LOOP x y |
causes the envelope on CV output x to loop for y times; a y of 0 will cause the envelope to loop infinitely; setting y to 1 (default) disables looping and (if currently looping) will cause it to finish its current cycle and cease |
||
TO.TR.INIT x |
initializes TR output x back to the default boot settings and behaviors; neutralizes metronomes, dividers, pulse counters, etc. |
||
TO.CV.INIT x |
initializes CV output x back to the default boot settings and behaviors; neutralizes offsets, slews, envelopes, oscillation, etc. |
||
TO.INIT d |
initializes all of the TR and CV outputs for device number d (1-8) |
||
TO.KILL d |
cancels all TR pulses and CV slews for device number d (1-8) |
TO.TR.PULSE.DIV
TO.TR.PULSE.DIV x y
- alias:
TO.TR.P.DIV
The pulse divider will output one trigger pulse every y
pulse commands. For example, setting the DIV
factor to 2
like this:
TO.TR.P.DIV 1 2
Will cause every other TO.TR.P 1
command to emit a pulse.
Reset it to one (TO.TR.P.DIV 1 1
) or initialize the output (TO.TR.INIT 1
) to return to the default behavior.
TO.TR.WIDTH
TO.TR.WIDTH x y
The actual time value for the trigger pulse when set by the WIDTH
command is relative to the current value for TO.TR.M
. Changes to TO.TR.M
will change the duration of TR.PULSE
when using the WIDTH
mode to set its value. Values for y
are set in percentage (0-100).
For example:
TO.TR.M 1 1000
TO.TR.WIDTH 1 50
The length of a TR.PULSE
is now 500ms.
TO.TR.M 1 500
The length of a TR.PULSE
is now 250ms. Note that you don’t need to use the width command again as it automatically tracks the value for TO.TR.M
.
TO.TR.M.ACT
TO.TR.M.ACT x y
Each TR
output has its own independent metronome that will execute a TR.PULSE
at a specified interval. The ACT
command enables (1) or disables (0) the metronome.
TO.TR.M.COUNT
TO.TR.M.COUNT x y
This allows for setting a limit to the number of times TO.TR.M
will PULSE
when active before automatically disabling itself. For example, let’s set it to pulse 5 times with 500ms between pulses:
TO.TR.M 1 500
TO.TR.M.COUNT 1 5
Now, each time we activate it, the metronome will pulse 5 times - each a half-second apart.
TO.TR.M.ACT 1 1
PULSE
… PULSE
… PULSE
… PULSE
… PULSE
.
The metronome is now disabled after pulsing five times. If you call ACT
again, it will emit five more pulses.
To reset, either set your COUNT
to zero (TO.TR.M.COUNT 1 0
) or call init on the output (TO.TR.INIT 1 1
).
TO.TR.M.MUL
TO.TR.M.MUL x y
The following example will cause 2 against 3 patterns to pulse out of TO.TR
outputs 3
and 4
.
TO.TR.M.MUL 3 2
TO.TR.M.MUL 4 3
L 3 4: TO.TR.M.ACT I 1
TO.M.SYNC
TO.M.SYNC d
This command causes the TXo at device d
to synchronize all of its independent metronomes to the moment it receives the command. Each will then continue to pulse at its own independent M
rate.
TO.CV.SCALE
TO.CV.SCALE x y
Quantization Scales
- Equal Temperament [DEFAULT]
- 12-tone Pythagorean scale
- Vallotti & Young scale (Vallotti version) also known as Tartini-Vallotti (1754)
- Andreas Werckmeister’s temperament III (the most famous one, 1681)
- Wendy Carlos’ Alpha scale with perfect fifth divided in nine
- Wendy Carlos’ Beta scale with perfect fifth divided by eleven
- Wendy Carlos’ Gamma scale with third divided by eleven or fifth by twenty
- Carlos Harmonic & Ben Johnston’s scale of ‘Blues’ from Suite f.micr.piano (1977) & David Beardsley’s scale of ‘Science Friction’
- Carlos Super Just
- Kurzweil “Empirical Arabic”
- Kurzweil “Just with natural b7th”, is Sauveur Just with 7/4
- Kurzweil “Empirical Bali/Java Harmonic Pelog”
- Kurzweil “Empirical Bali/Java Slendro, Siam 7”
- Kurzweil “Empirical Tibetian Ceremonial”
- Harry Partch’s 43-tone pure scale
- Partch’s Indian Chromatic, Exposition of Monophony, 1933.
- Partch Greek scales from “Two Studies on Ancient Greek Scales” on black/white
TO.CV.LOG
TO.CV.LOG x y
The following example creates an envelope that ramps to 5V over a logarithmic curve:
TO.CV.SET 1 V 5
TO.CV.LOG 1 2
TO.ENV.ATT 1 500
TO.ENV.DEC.S 1 2
TO.ENV.ACT 1 1
When triggered (TO.ENV.TRIG 1
), the envelope will rise to 5V over a half a second and then decay back to zero over two seconds. The curve used is 2
, which covers 0V-5V.
If a curve is too small for the range being covered, values above the range will be limited to the range’s ceiling. In the above example, voltages above 5V will all return as 5V.
TO.CV.CALIB
TO.CV.CALIB x
To calibrate your TXo outputs, follow these steps. Before you start, let your expander warm up for a few minutes. It won’t take long - but you want to make sure that it is calibrated at a more representative temperature.
Then, first adjust your offset (CV.OFF) until the output is at zero volts (0). For example:
CV.OFF 1 8
Once that output measures at zero volts, you want to lock it in as the calibration by calling the following operator:
CV.CALIB 1
You will find that the offset is now zero, but the output is at the value that you targeted during your prior adjustment. To reset to normal (and forget this calibration offset), use the TO.CV.RESET
command.
TO.OSC
TO.OSC x y
Setting an OSC
frequency greater than zero for a CV
output will start that output oscillating. It will swing its voltage between to the current CV
value and its polar opposite. For example:
TO.CV 1 V 5
TO.OSC 1 N 69
This will emit the audio-rate note A (at 440Hz) swinging from ‘+5V’ to ‘-5V’. The CV
value acts as an amplitude control. For example:
TO.CV.SLEW.M 1 1
TO.CV 1 V 10
This will cause the oscillations to gradually increase in amplitude from 5V
to 10V
over a period of one minute.
IMPORANT: if you do not set a CV
value, the oscillator will not emit a signal.
If you want to go back to regular CV
behavior, you need to set the oscillation frequency to zero. E.g. TO.OSC 1 0
. You can also initialize the CV
output with TO.CV.INIT 1
, which resets all of its settings back to start-up default.
TO.OSC.SCALE
TO.OSC.SCALE x y
Quantization Scales
- Equal Temperament [DEFAULT]
- 12-tone Pythagorean scale
- Vallotti & Young scale (Vallotti version) also known as Tartini-Vallotti (1754)
- Andreas Werckmeister’s temperament III (the most famous one, 1681)
- Wendy Carlos’ Alpha scale with perfect fifth divided in nine
- Wendy Carlos’ Beta scale with perfect fifth divided by eleven
- Wendy Carlos’ Gamma scale with third divided by eleven or fifth by twenty
- Carlos Harmonic & Ben Johnston’s scale of ‘Blues’ from Suite f.micr.piano (1977) & David Beardsley’s scale of ‘Science Friction’
- Carlos Super Just
- Kurzweil “Empirical Arabic”
- Kurzweil “Just with natural b7th”, is Sauveur Just with 7/4
- Kurzweil “Empirical Bali/Java Harmonic Pelog”
- Kurzweil “Empirical Bali/Java Slendro, Siam 7”
- Kurzweil “Empirical Tibetian Ceremonial”
- Harry Partch’s 43-tone pure scale
- Partch’s Indian Chromatic, Exposition of Monophony, 1933.
- Partch Greek scales from “Two Studies on Ancient Greek Scales” on black/white
TO.OSC.RECT
TO.OSC.RECT x y
The rectification command performs a couple of levels of rectification based on how you have it set. The following values for y
work as follows:
y = 2
: “full-positive” - inverts negative values, making them positivey = 1
: “half-positive” - omits all negative values (values below zero are set to zero)y = 0
: no rectification (default)y = -1
: “half-negative” - omits all positive values (values above zero are set to zero)y = -2
: “full-negative” - inverts positive values, making them negative
TO.OSC.SLEW
TO.OSC.SLEW x y
This parameter acts as a frequency slew for the targeted CV
output. It allows you to gradually slide from one frequency to another, creating a portamento like effect. It is also great for smoothing transitions between different LFO
rates on the oscillator. For example:
TO.CV 1 V 5
TO.OSC.SLEW 1 30000
TO.OSC.LFO.SET 1 1000
TO.OSC.LFO 1 100
This will start an LFO on CV 1
with a rate of 1000mHz. Then, over the next 30 seconds, it will gradually decrease in rate to 100mHz.
TO.OSC.CTR
TO.OSC.CTR x y
For example, to create a sine wave that is centered at 2.5V and swings up to +5V and down to 0V, you would do this:
TO.CV 1 VV 250
TO.OSC.CTR 1 VV 250
TO.OSC.LFO 1 500
TO.ENV.ACT
TO.ENV.ACT x y
This setting activates (1) or deactivates (0) the envelope generator on CV
output y
. The envelope generator is dependent on the current voltage setting for the output. Upon activation, the targeted output will go to zero. Then, when triggered (TO.ENV.TRIG
), it will ramp the voltage from zero to the currently set peak voltage (TO.CV
) over the attack time (TO.ENV.ATT
) and then decay back to zero over the decay time (TO.ENV.DEC
). For example:
TO.CV.SET 1 V 8
TO.ENV.ACT 1 1
TO.ENV.ATT.S 1 1
TO.ENV.DEC.S 1 30
This will initialize the CV 1
output to have an envelope that will ramp to +8V
over one second and decay back to zero over thirty seconds. To trigger the envelope, you need to send the trigger command TO.ENV.TRIG 1
. Envelopes currently re-trigger from the start of the cycle.
To return your CV
output to normal function, either deactivate the envelope (TO.ENV.ACT 1 0
) or reinitialize the output (TO.CV.INIT 1
).
TO.ENV.EOR
TO.ENV.EOR x n
The most important thing to know with this operator is that you can only cause the EOR trigger to fire on the same device as the TXo with the envelope. For this command, the outputs are numbered LOCALLY to the unit with the envelope.
For example, if you have an envelope running on your second TXo, you can only send the EOR pulse to the four outputs on that device:
TO.ENV.EOR 5 1
This will cause the first output on TXo #2 (TO.TR 5
) to pulse after the envelope’s attack segment.
TO.ENV.EOC
TO.ENV.EOC x n
The most important thing to know with this operator is that you can only cause the EOC trigger to fire on the same device as the TXo with the envelope. For this command, the outputs are numbered LOCALLY to the unit with the envelope.
For example, if you have an envelope running on your second TXo, you can only send the EOC pulse to the four outputs on that device:
TO.ENV.EOC 5 1
This will cause the first output on TXo #2 (TO.TR 5
) to pulse after the envelope’s decay segment.
Orthogonal Devices ER-301 Sound Computer
The ER-301 is a voltage-controllable canvas for digital signal processing algorithms available from Orthogonal Devices. It can communicate with the Teletype to send up to 100 triggers and 100 CV values per device. Up to three devices are software-selectable and correlate to outputs up to 300.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
SC.TR x y |
Set trigger output for the ER-301 virtual output x to y (0-1) | ||
SC.TR.POL x y |
Set polarity of trigger for the ER-301 virtual output x to y (0-1) | ||
SC.TR.TIME x y |
Set the pulse time for the ER-301 virtual trigger x to y in ms |
||
SC.TR.TOG x |
Flip the state for the ER-301 virtual trigger output x |
||
SC.TR.PULSE x |
SC.TR.P |
Pulse the ER-301 virtual trigger output x |
|
SC.CV x y |
CV target value for the ER-301 virtual output x to value y |
||
SC.CV.OFF x y |
CV offset added to the ER-301 virtual output x |
||
SC.CV.SET x |
Set CV value for the ER-301 virtual output x |
||
SC.CV.SLEW x y |
Set the CV slew time for the ER-301 virtual output x in ms |
16n Faderbank
The 16n Faderbank is an open-source controller that can be polled by the Teletype to read the positions of its 16 sliders.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
FADER x |
FB |
reads the value of the FADER slider x ; default return range is from 0 to 16383 |
W/
More extensively covered in the W/ Documentation.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
WS.PLAY x |
Set playback state and direction. 0 stops playback. 1 sets forward motion, while -1 plays in reverse |
||
WS.REC x |
Set recording mode. 0 is playback only. 1 sets overdub mode for additive recording. -1 sets overwrite mode to replace the tape with your input |
||
WS.CUE x |
Go to a cuepoint relative to the playhead position. 0 retriggers the current location. 1 jumps to the next cue forward. -1 jumps to the previous cue in the reverse. These actions are relative to playback direction such that 0 always retriggers the most recently passed location |
||
WS.LOOP x |
Set the loop state on/off. 0 is off. Any other value turns loop on |
Matrixarchate
The SSSR Labs SM010 Matrixarchate is a 16x8 IO Sequenceable Matrix Signal Router.
OP | OP (set) | (aliases) | Description |
---|---|---|---|
MA.SELECT x |
select the default matrixarchate module, default 1 |
||
MA.STEP |
advance program sequencer | ||
MA.RESET |
reset program sequencer | ||
MA.PGM pgm |
select the current program (1-based) | ||
MA.ON x y |
connect row x and column y in the current program (rows/columns are 0-based) |
||
MA.PON pgm x y |
connect row x and column y in program pgm |
||
MA.OFF x y |
disconnect row x and column y in the current program |
||
MA.POFF x y pgm |
connect row x and column y in program pgm |
||
MA.SET x y state |
set the connection at row x and column y to state (1 - on, 0 - off) |
||
MA.PSET pgm x y state |
set the connection at row x and column y in program pgm to state (1 - on, 0 - off) |
||
MA.COL col |
MA.COL col value |
get or set column col (as a 16 bit unsigned value where each bit represents a connection) |
|
MA.PCOL pgm col |
MA.PCOL pgm col value |
get or set column col in program pgm |
|
MA.ROW row |
MA.ROW row value |
get or set row row |
|
MA.PROW pgm row |
MA.PROW pgm row value |
get or set row row in program pgm |
|
MA.CLR |
clear all connections | ||
MA.PCLR pgm |
clear all connections in program pgm |
Advanced
Teletype terminology
Here is a picture to help understand the naming of the various parts of a Teletype command:
COMMAND
The entire command, e.g.
IF X: Y 1; Z 2;
.PRE
The (optional) part before the
PRE SEP
, e.g.IF X
.POST
The part after the PRE SEP, e.g.
Y 1; Z 2
.SUB
A sub command (only allowed in the
POST
), e.g.Y 1
, orZ 2
.PRE SEP
A colon, only one is allowed.
SUB SEP
A semi-colon, that separates sub commands (if used), only allowed in the
POST
.NUM
A number between
−32768
and32767
.OP
An operator, e.g.
X
,TR.PULSE
MOD
A modifier, e.g.
IF
, orL
.
Sub commands
Sub commands allow you to run multiple commands on a single line by utilising a semi-colon to separate each command, for example the following script:
X 0
Y 1
Z 2
Can be rewritten using sub commands as:
X 0; Y 1; Z 2
On their own sub commands allow for an increased command density on the Teletype. However when combined with PRE
statements, certain operations become a lot easier.
Firstly, sub commands cannot be used before a MOD
or in the PRE
itself. For example, the following is not allowed:
X 1; IF X: TR.PULSE 1
We can use them in the POST
though, particularly with an IF
, for example:
IF X: CV 1 N 60; TR.P 1
IF Y: TR.P 1; TR.P 2; TR.P 3
Sub commands can also be used with L
, though due to (current) limitations on how many separate numbers, OP
s and MOD
s are allowed in a single command this can be tricky (even if you can fit the text on a line).
Aliases
In general, aliases are a simple concept to understand. Certain OP
s have been given shorted names to save space and the amount of typing, for example:
TR.PULSE 1
Can be replaced with:
TR.P 1
Where confusion may arise is with the symbolic aliases that have been given to some of the maths OP
s. For instance +
is given as an alias for ADD
and it must be used as a direct replacement:
X ADD 1 1
X + 1 1
The key to understanding this is that the Teletype uses prefix notation2 always, even when using mathematical symbols.
The following example (using infix notation) will not work:
X 1 + 1
Aliases are entirely optional, most OP
s do not have aliases. Consult the OP
tables and documentation to find them.
Avoiding non-determinism
Although happy accidents in the modular world are one of it’s many joys, when writing computer programs they can be incredibly frustrating. Here are some small tips to help keep things predictable (when you want to them to be):
Don’t use variables unless you need to.
This is not to say that variables are not useful, rather it’s the opposite and they are extremely powerful. But it can be hard to keep a track of what each variable is used for and on which script it is used. Rather, try to save using variables for when you do want non-deterministic (i.e. variable) behaviour.
Consider using
I
as a temporary variable.If you do find yourself needing a variable, particularly one that is used to continue a calculation on another line, consider using the variable
I
. Unlike the other variables,I
is overwritten wheneverL
is used, and as such, is implicitly transient in nature. One should never need to worry about modifying the value ofI
and causing another script to malfunction, as no script should ever assume the value ofI
.Use
PN
versions ofOP
s.Most
P
OP
s are now available asPN
versions that ignore the value ofP.I
. (e.g.PN.START
forP.START
). Unless you explicitly require the non-determinism ofP
versions, stick to thePN
versions (space allowing).Avoid using
A
,B
,C
andD
to refer to the trigger outputs, instead use the numerical values directly.As
A-D
are variables, they may no longer contain the values1-4
, and while this was the recommend way to name triggers, it is no longer consider ideal. Newer versions of the Teletype hardware have replaced the labels on the trigger outputs, with the numbers1
to4
.
Grid integration
Grid integration can be described very simply: it allows you to use grid with teletype. However, there is more to it than just that. You can create custom grid interfaces that can be tailored individually for each scene. Since it’s done with scripts you can dynamically change these interfaces at any point - you could even create a dynamic interface that reacts to the scene itself or incoming triggers or control voltages.
It’s hard to describe what can be done as there are so many different ways you can use it. You can simply use grid as an LED display to visualize your scene. Or make it into an earthsea style keyboard. You can create sequencers, or control surfaces to control other sequencers.
There are many grid operators intended to simplify building very complex interfaces, while something simple like a bank of faders can be done with just two lines of scripts (and can be just as useful!).
As you can’t have both keyboard and grid connected at the same time, the Grid Visualizer is provided in Live screen so you can see exactly what it will look like on the actual grid. You can even use it to emulate grid presses so you can test your scene too. As a matter of fact, it’s entirely possible to use grid scenes without a grid just by using the Visualizer.
If you don’t feel like creating your own interfaces you can take advantage of the Grid Control mode. It allows you to use grid to trigger and mute scripts, edit variables and tracker values, save and load scenes, and more.
As there are many topics to cover, the best way to start learning Grid integration is by following the Grid Studies.
Alphabetical list of OPs and MODs
OP | OP (set) | (aliases) | Description |
---|---|---|---|
& x y |
bitwise and x & y |
||
? x y z |
if condition x is true return y , otherwise return z |
||
@ |
@ x |
get or set the current pattern value under the turtle | |
@BOUNCE |
@BOUNCE 1 |
get whether the turtle fence mode is BOUNCE, or set it to BOUNCE with 1 | |
@BUMP |
@BUMP 1 |
get whether the turtle fence mode is BUMP, or set it to BUMP with 1 | |
@DIR |
@DIR x |
get the direction of the turtle’s @STEP in degrees or set it to x | |
@F x1 y1 x2 y2 |
set the turtle’s fence to corners x1,y1 and x2,y2 | ||
@FX1 |
@FX1 x |
get the left fence line or set it to x | |
@FX2 |
@FX2 x |
get the right fence line or set it to x | |
@FY1 |
@FY1 x |
get the top fence line or set it to x | |
@FY2 |
@FY2 x |
get the bottom fence line or set it to x | |
@MOVE x y |
move the turtle x cells in the X axis and y cells in the Y axis | ||
@SCRIPT |
@SCRIPT x |
get which script runs when the turtle changes cells, or set it to x | |
@SHOW |
@SHOW 0/1 |
get whether the turtle is displayed on the TRACKER screen, or turn it on or off | |
@SPEED |
@SPEED x |
get the speed of the turtle’s @STEP in cells per step or set it to x | |
@STEP |
move @SPEED /100 cells forward in @DIR , triggering @SCRIPT on cell change |
||
@WRAP |
@WRAP 1 |
get whether the turtle fence mode is WRAP, or set it to WRAP with 1 | |
@X |
@X x |
get the turtle X coordinate, or set it to x | |
@Y |
@Y x |
get the turtle Y coordinate, or set it to x | |
A |
A x |
get / set the variable A , default 1 |
|
ABS x |
absolute value of x |
||
ADD x y |
+ |
add x and y together |
|
AND x y |
&& |
logical AND of x and y |
|
ARP.DIV v d |
set voice clock divisor (euclidean length), range [1-32] | ||
ARP.ER v f d r |
set all euclidean rhythm | ||
ARP.FIL v f |
set voice euclidean fill, use 1 for straight clock division, range [1-32] | ||
ARP.GT v g |
set voice gate length [0-127], scaled/synced to course divisions of voice clock | ||
ARP.HLD h |
0 disables key hold mode, other values enable |
||
ARP.RES v |
reset voice clock/pattern on next base clock tick | ||
ARP.ROT v r |
set voice euclidean rotation, range [-32, 32] | ||
ARP.RPT v n s |
set voice pattern repeat, n times [0-8], shifted by s semitones [-24, 24] |
||
ARP.SHIFT v o |
shift voice cv by standard tt pitch value (e.g. N 6, V -1, etc) | ||
ARP.SLEW v t |
set voice slew time in ms | ||
ARP.STY y |
set base arp style [0-7] | ||
AVG x y |
the average of x and y |
||
B |
B x |
get / set the variable B , default 2 |
|
BCLR x y |
clear bit y in value x |
||
BGET x y |
get bit y in value x |
||
BPM x |
milliseconds per beat in BPM x |
||
BREAK |
BRK |
halts execution of the current script | |
BSET x y |
set bit y in value x |
||
C |
C x |
get / set the variable C , default 3 |
|
CHAOS x |
get next value from chaos generator, or set the current value | ||
CHAOS.ALG x |
get or set the algorithm for the CHAOS generator. 0 = LOGISTIC, 1 = CUBIC, 2 = HENON, 3 = CELLULAR |
||
CHAOS.R x |
get or set the R parameter for the CHAOS generator |
||
CV x |
CV x y |
CV target value | |
CV.OFF x |
CV.OFF x y |
CV offset added to output | |
CV.SET x |
Set CV value | ||
CV.SLEW x |
CV.SLEW x y |
Get/set the CV slew time in ms | |
CY.CV x |
get the current CV value for channel x |
||
CY.POS x |
CY.POS x y |
get / set position of channel x (x = 0 to set all), position between 0-255 |
|
CY.PRE |
CY.PRE x |
return current preset / load preset x |
|
CY.RES x |
reset channel x (0 = all) |
||
CY.REV x |
reverse channel x (0 = all) |
||
D |
D x |
get / set the variable D , default 4 |
|
DEL x: ... |
Delay command by x ms |
||
DEL.CLR |
Clear the delay buffer | ||
DIV x y |
/ |
divide x by y |
|
DRUNK |
DRUNK x |
changes by -1 , 0 , or 1 upon each read saving its state, setting will give it a new value for the next read |
|
DRUNK.MAX |
DRUNK.MAX x |
set the upper bound for DRUNK , default 255 |
|
DRUNK.MIN |
DRUNK.MIN x |
set the lower bound for DRUNK , default 0 |
|
DRUNK.WRAP |
DRUNK.WRAP x |
should DRUNK wrap around when it reaches it’s bounds, default 0 |
|
ELIF x: ... |
if all previous IF / ELIF fail, and x is not zero, execute command |
||
ELSE: ... |
if all previous IF / ELIF fail, excute command |
||
EQ x y |
== |
does x equal y |
|
ER f l i |
Euclidean rhythm, f is fill (1-32 ), l is length (1-32 ) and i is step (any value), returns 0 or 1 |
||
ES.CLOCK x |
If II clocked, next pattern event | ||
ES.MAGIC x |
Magic shape (1= halfspeed, 2=doublespeed, 3=linearize) | ||
ES.MODE x |
Set pattern clock mode. (0=normal, 1=II clock) | ||
ES.PATTERN x |
Select playing pattern (0-15) | ||
ES.PRESET x |
Recall preset x (0-7) |
||
ES.RESET x |
Reset pattern to start (and start playing) | ||
ES.STOP x |
Stop pattern playback. | ||
ES.TRANS x |
Transpose the current pattern | ||
ES.TRIPLE x |
Recall triple shape (1-4) | ||
EVERY x: ... |
run the command every x times the command is called |
||
EXP x |
exponentiation table lookup. 0-16383 range (V 0-10 ) |
||
EZ x |
! |
x is 0 , equivalent to logical NOT |
|
FADER x |
FB |
reads the value of the FADER slider x ; default return range is from 0 to 16383 |
|
FLIP |
FLIP x |
returns inverted state (0 or 1 ) on each read (also settable) |
|
G.BTN id x y w h type level script |
initialize button | ||
G.BTN.EN id |
G.BTN.EN id x |
enable/disable button or check if enabled | |
G.BTN.L id |
G.BTN.L id level |
get/set button level | |
G.BTN.PR id action |
emulate button press/release | ||
G.BTN.SW id |
switch button | ||
G.BTN.V id |
G.BTN.V id value |
get/set button value | |
G.BTN.X id |
G.BTN.X id x |
get/set button x coordinate | |
G.BTN.Y id |
G.BTN.Y id y |
get/set button y coordinate | |
G.BTNI |
id of last pressed button | ||
G.BTNL |
G.BTNL level |
get/set level of last pressed button | |
G.BTNV |
G.BTNV value |
get/set value of last pressed button | |
G.BTNX |
G.BTNX x |
get/set x of last pressed button | |
G.BTNY |
G.BTNY y |
get/set y of last pressed button | |
G.BTX id x y w h type level script columns rows |
initialize multiple buttons | ||
G.CLR |
clear all LEDs | ||
G.DIM level |
set dim level | ||
G.FDR id x y w h type level script |
initialize fader | ||
G.FDR.EN id |
G.FDR.EN id x |
enable/disable fader or check if enabled | |
G.FDR.L id |
G.FDR.L id level |
get/set fader level | |
G.FDR.N id |
G.FDR.N id value |
get/set fader value | |
G.FDR.PR id value |
emulate fader press | ||
G.FDR.V id |
G.FDR.V id value |
get/set scaled fader value | |
G.FDR.X id |
G.FDR.X id x |
get/set fader x coordinate | |
G.FDR.Y id |
G.FDR.Y id y |
get/set fader y coordinate | |
G.FDRI |
id of last pressed fader | ||
G.FDRL |
G.FDRL level |
get/set level of last pressed fader | |
G.FDRN |
G.FDRN value |
get/set value of last pressed fader | |
G.FDRV |
G.FDRV value |
get/set scaled value of last pressed fader | |
G.FDRX |
G.FDRX x |
get/set x of last pressed fader | |
G.FDRY |
G.FDRY y |
get/set y of last pressed fader | |
G.FDX id x y w h type level script columns rows |
initialize multiple faders | ||
G.GBT group id x y w h type level script |
initialize button in group | ||
G.GBTN.C group |
get count of currently pressed | ||
G.GBTN.H group |
get button block height | ||
G.GBTN.I group index |
get id of pressed button | ||
G.GBTN.L group odd_level even_level |
set level for group buttons | ||
G.GBTN.V group value |
set value for group buttons | ||
G.GBTN.W group |
get button block width | ||
G.GBTN.X1 group |
get leftmost pressed x | ||
G.GBTN.X2 group |
get rightmost pressed x | ||
G.GBTN.Y1 group |
get highest pressed y | ||
G.GBTN.Y2 group |
get lowest pressed y | ||
G.GBX group id x y w h type level script columns rows |
initialize multiple buttons in group | ||
G.GFD grp id x y w h type level script |
initialize fader in group | ||
G.GFDR.L group odd_level even_level |
set level for group faders | ||
G.GFDR.N group value |
set value for group faders | ||
G.GFDR.RN group min max |
set range for group faders | ||
G.GFDR.V group value |
set scaled value for group faders | ||
G.GFX group id x y w h type level script columns rows |
initialize multiple faders in group | ||
G.GRP |
G.GRP id |
get/set current group | |
G.GRP.EN id |
G.GRP.EN id x |
enable/disable group or check if enabled | |
G.GRP.RST id |
reset all group controls | ||
G.GRP.SC id |
G.GRP.SC id script |
get/set group script | |
G.GRP.SW id |
switch groups | ||
G.GRPI |
get last group | ||
G.KEY x y action |
emulate grid press | ||
G.LED x y |
G.LED x y level |
get/set LED | |
G.LED.C x y |
clear LED | ||
G.RCT x1 y1 x2 y2 fill border |
draw rectangle | ||
G.REC x y w h fill border |
draw rectangle | ||
G.ROTATE x |
set grid rotation | ||
G.RST |
full grid reset | ||
GT x y |
> |
x is greater than y |
|
GTE x y |
>= |
x is greater than or equal to y |
|
I |
I x |
get / set the variable I |
|
IF x: ... |
if x is not zero execute command |
||
IN |
Get the value of IN jack (0-16383) | ||
IN.CAL.MAX |
Reads the input CV and assigns the voltage to the max point | ||
IN.CAL.MIN |
Reads the input CV and assigns the voltage to the zero point | ||
IN.SCALE min max |
Set static scaling of the IN CV to between min and max . |
||
INIT |
clears all state data | ||
INIT.CV x |
clears all parameters on CV associated with output x | ||
INIT.CV.ALL |
clears all parameters on all CV’s | ||
INIT.DATA |
clears all data held in all variables | ||
INIT.P x |
clears pattern associated with pattern number x | ||
INIT.P.ALL |
clears all patterns | ||
INIT.SCENE |
loads a blank scene | ||
INIT.SCRIPT x |
clear script number x | ||
INIT.SCRIPT.ALL |
clear all scripts | ||
INIT.TIME x |
clear time on trigger x | ||
INIT.TR x |
clear all parameters on trigger associated with TR x | ||
INIT.TR.ALL |
clear all triggers | ||
JF.GOD x |
Redefines C3 to align with the ‘God’ note. x = 0 sets A to 440, x = 1 sets A to 432. |
||
JF.MODE x |
Set the current choice of standard functionality, or Just Type alternate modes. You’ll likely want to put JF.MODE x in your Teletype INIT scripts. x = nonzero activates alternative modes. 0 restores normal. |
||
JF.NOTE x y |
Polyphonically allocated note sequencing. Works as JF.VOX with chan selected automatically. Free voices will be taken first. If all voices are busy, will steal from the voice which has been active the longest. x = pitch relative to C3, y = velocity. |
||
JF.QT x |
When non-zero, all events are queued & delayed until the next quantize event occurs. Using values that don’t align with the division of rhythmic streams will cause irregular patterns to unfold. Set to 0 to deactivate quantization. x = division, 0 deactivates quantization, 1 to 32 sets the subdivision & activates quantization. |
||
JF.RMODE x |
Set the RUN state of Just Friends when no physical jack is present. (0 = run off, non-zero = run on) |
||
JF.RUN x |
Send a ‘voltage’ to the RUN input. Requires JF.RMODE 1 to have been executed, or a physical cable in JF’s input. Thus Just Friend’s RUN modes are accessible without needing a physical cable & control voltage to set the RUN parameter. use JF.RUN V x to set to x volts. The expected range is V -5 to V 5 |
||
JF.SHIFT x |
Shifts the transposition of Just Friends, regardless of speed setting. Shifting by V 1 doubles the frequency in sound, or doubles the rate in shape. x = pitch, use N x for semitones, or V y for octaves. |
||
JF.TICK x |
Sets the underlying timebase of the Geode. x = clock. 0 resets the timebase to the start of measure. 1 to 48 shall be sent repetitively. The value representing ticks per measure. 49 to 255 sets beats-per-minute and resets the timebase to start of measure. |
||
JF.TR x y |
Simulate a TRIGGER input. x is channel (0 = all) and y is state (0 or 1 ) |
||
JF.TUNE x y z |
Adjust the tuning ratios used by the INTONE control. x = channel, y = numerator (set the multiplier for the tuning ratio), z = denominator (set the divisor for the tuning ratio). |
||
JF.VOX x y z |
Create a note at the specified channel, of the defined pitch & velocity. All channels can be set simultaneously with a chan value of 0. x = channel, y = pitch relative to C3, z = velocity (like JF.VTR ). |
||
JF.VTR x y |
Like JF.TR with added volume control. Velocity is scaled with volts, so try V 5 for an output trigger of 5 volts. Channels remember their latest velocity setting and apply it regardless of TRIGGER origin (digital or physical). x = channel, 0 sets all channels. y = velocity, amplitude of output in volts. eg JF.VTR 1 V 4 . |
||
JI x y |
just intonation helper, precision ratio divider normalised to 1V | ||
KILL |
clears stack, clears delays, cancels pulses, cancels slews, disables metronome | ||
KR.CLK x |
advance the clock for channel x (channel must have teletype clocking enabled) |
||
KR.CV x |
get the current CV value for channel x |
||
KR.L.LEN x y |
KR.L.LEN x y z |
get length of track x , parameter y / set to z |
|
KR.L.ST x y |
KR.L.ST x y z |
get loop start for track x , parameter y / set to z |
|
KR.MUTE x |
KR.MUTE x y |
get/set mute state for channel x (1 = muted, 0 = unmuted) |
|
KR.PAT |
KR.PAT x |
get/set current pattern | |
KR.PERIOD |
KR.PERIOD x |
get/set internal clock period | |
KR.POS x y |
KR.POS x y z |
get/set position z for track z , parameter y |
|
KR.PRE |
KR.PRE x |
return current preset / load preset x |
|
KR.RES x y |
reset position to loop start for track x , parameter y |
||
KR.SCALE |
KR.SCALE x |
get/set current scale | |
KR.TMUTE x |
toggle mute state for channel x |
||
L x y: ... |
run the command sequentially with I values from x to y |
||
LAST x |
get value in milliseconds since last script run time | ||
LIM x y z |
limit the value x to the range y to z inclusive |
||
LSH x y |
<< |
left shift x by y bits, in effect multiply x by 2 to the power of y |
|
LT x y |
< |
x is less than y |
|
LTE x y |
<= |
x is less than or equal to y |
|
LV.CV x |
get the current CV value for channel x |
||
LV.L.DIR |
LV.L.DIR x |
get/set loop direction | |
LV.L.LEN |
LV.L.LEN x |
get/set loop length | |
LV.L.ST |
LV.L.ST x |
get/set loop start | |
LV.POS |
LV.POS x |
get/set current position | |
LV.PRE |
LV.PRE x |
return current preset / load preset x |
|
LV.RES x |
reset, 0 for soft reset (on next ext. clock), 1 for hard reset |
||
M |
M x |
get/set metronome interval to x (in ms), default 1000 , minimum value 25 |
|
M! |
M! x |
get/set metronome to experimental interval x (in ms), minimum value 2 |
|
M.ACT |
M.ACT x |
get/set metronome activation to x (0/1 ), default 1 (enabled) |
|
M.RESET |
hard reset metronome count without triggering | ||
MA.CLR |
clear all connections | ||
MA.COL col |
MA.COL col value |
get or set column col (as a 16 bit unsigned value where each bit represents a connection) |
|
MA.OFF x y |
disconnect row x and column y in the current program |
||
MA.ON x y |
connect row x and column y in the current program (rows/columns are 0-based) |
||
MA.PCLR pgm |
clear all connections in program pgm |
||
MA.PCOL pgm col |
MA.PCOL pgm col value |
get or set column col in program pgm |
|
MA.PGM pgm |
select the current program (1-based) | ||
MA.POFF x y pgm |
connect row x and column y in program pgm |
||
MA.PON pgm x y |
connect row x and column y in program pgm |
||
MA.PROW pgm row |
MA.PROW pgm row value |
get or set row row in program pgm |
|
MA.PSET pgm x y state |
set the connection at row x and column y in program pgm to state (1 - on, 0 - off) |
||
MA.RESET |
reset program sequencer | ||
MA.ROW row |
MA.ROW row value |
get or set row row |
|
MA.SELECT x |
select the default matrixarchate module, default 1 |
||
MA.SET x y state |
set the connection at row x and column y to state (1 - on, 0 - off) |
||
MA.STEP |
advance program sequencer | ||
MAX x y |
return the maximum of x and y |
||
ME.CV x |
get the current CV value for channel x |
||
ME.PERIOD |
ME.PERIOD x |
get/set internal clock period | |
ME.PRE |
ME.PRE x |
return current preset / load preset x |
|
ME.RES x |
reset channel x (0 = all), also used as “start” |
||
ME.SCALE |
ME.SCALE x |
get/set current scale | |
ME.STOP x |
stop channel x (0 = all) |
||
MID.SHIFT o |
shift pitch CV by standard Teletype pitch value (e.g. N 6 , V -1 , etc) |
||
MID.SLEW t |
set pitch slew time in ms (applies to all allocation styles except FIXED) | ||
MIN x y |
return the minimum of x and y |
||
MOD x y |
% |
find the remainder after division of x by y |
|
MP.PRESET x |
set Meadowphysics to preset x (indexed from 0 ) |
||
MP.RESET x |
reset countdown for channel x (0 = all, 1-8 = individual channels) |
||
MP.STOP x |
reset channel x (0 = all, 1-8 = individual channels) |
||
MUL x y |
* |
multiply x and y together |
|
MUTE x |
MUTE x y |
Disable trigger input x | |
N x |
converts an equal temperament note number to a value usable by the CV outputs (x in the range -127 to 127 ) |
||
NE x y |
!= , XOR |
x is not equal to y |
|
NZ x |
x is not 0 |
||
O |
O x |
auto-increments after each access, can be set, starting value 0 |
|
O.INC |
O.INC x |
how much to increment O by on each invocation, default 1 |
|
O.MAX |
O.MAX x |
the upper bound for O , default 63 |
|
O.MIN |
O.MIN x |
the lower bound for O , default 0 |
|
O.WRAP |
O.WRAP x |
should O wrap when it reaches its bounds, default 1 |
|
OR x y |
|| |
logical OR of x and y |
|
OR.BANK x |
Select preset bank x (1-8 ) |
||
OR.CLK x |
Advance track x (1-4 ) |
||
OR.CVA x |
Select tracks for CV A where x is a binary number representing the tracks |
||
OR.CVB x |
Select tracks for CV B where x is a binary number representing the tracks |
||
OR.DIV x |
Set divisor for selected track to x (1-16 ) |
||
OR.GRST x |
Global reset (x can be any value) |
||
OR.MUTE x |
Mute trigger selected by OR.TRK (0 = on, 1 = mute) |
||
OR.PHASE x |
Set phase for selected track to x (0-16 ) |
||
OR.PRESET x |
Select preset x (1-8 ) |
||
OR.RELOAD x |
Reload preset or bank (0 - current preset, 1 - current bank, 2 - all banks) |
||
OR.ROTS x |
Rotate scales by x (1-15 ) |
||
OR.ROTW x |
Rotate weights by x (1-3 ) |
||
OR.RST x |
Reset track x (1-4 ) |
||
OR.SCALE x |
Select scale x (1-16 ) |
||
OR.TRK x |
Choose track x (1-4 ) to be used by OR.DIV , OR.PHASE , OR.WGT or OR.MUTE |
||
OR.WGT x |
Set weight for selected track to x (1-8 ) |
||
OTHER: ... |
runs the command when the previous EVERY /SKIP did not run its command. |
||
P x |
P x y |
get/set the value of the working pattern at index x |
|
P.+ x y |
increase the value of the working pattern at index x by y |
||
P.+W x y a b |
increase the value of the working pattern at index x by y and wrap it to a ..b range |
||
P.- x y |
decrease the value of the working pattern at index x by y |
||
P.-W x y a b |
decrease the value of the working pattern at index x by y and wrap it to a ..b range |
||
P.END |
P.END x |
get/set the end location of the working pattern, default 63 |
|
P.HERE |
P.HERE x |
get/set value at current index of working pattern | |
P.I |
P.I x |
get/set index position for the working pattern. | |
P.INS x y |
insert value y at index x of working pattern, shift later values down, destructive to loop length |
||
P.L |
P.L x |
get/set pattern length of the working pattern, non-destructive to data | |
P.MAX |
find the first maximum value in the pattern between the START and END for the working pattern and return its index | ||
P.MIN |
find the first minimum value in the pattern between the START and END for the working pattern and return its index | ||
P.N |
P.N x |
get/set the pattern number for the working pattern, default 0 |
|
P.NEXT |
P.NEXT x |
increment index of working pattern then get/set value | |
P.POP |
return and remove the value from the end of the working pattern (like a stack), destructive to loop length | ||
P.PREV |
P.PREV x |
decrement index of working pattern then get/set value | |
P.PUSH x |
insert value x to the end of the working pattern (like a stack), destructive to loop length |
||
P.RM x |
delete index x of working pattern, shift later values up, destructive to loop length |
||
P.RND |
return a value randomly selected between the start and the end position | ||
P.START |
P.START x |
get/set the start location of the working pattern, default 0 |
|
P.WRAP |
P.WRAP x |
when the working pattern reaches its bounds does it wrap (0/1 ), default 1 (enabled) |
|
PARAM |
PRM |
Get the value of PARAM knob (0-16383) | |
PARAM.CAL.MAX |
Reads the Paramter Knob maximum position and assigns the maximum point | ||
PARAM.CAL.MIN |
Reads the Parameter Knob minimum position and assigns a zero value | ||
PARAM.SCALE min max |
Set static scaling of the PARAM knob to between min and max . |
||
PN x y |
PN x y z |
get/set the value of pattern x at index y |
|
PN.+ x y z |
increase the value of pattern x at index y by z |
||
PN.+W x y z a b |
increase the value of pattern x at index y by z and wrap it to a ..b range |
||
PN.- x y z |
decrease the value of pattern x at index y by z |
||
PN.-W x y z a b |
decrease the value of pattern x at index y by z and wrap it to a ..b range |
||
PN.END x |
PN.END x y |
get/set the end location of the pattern x , default 63 |
|
PN.HERE x |
PN.HERE x y |
get/set value at current index of pattern x |
|
PN.I x |
PN.I x y |
get/set index position for pattern x |
|
PN.INS x y z |
insert value z at index y of pattern x , shift later values down, destructive to loop length |
||
PN.L x |
PN.L x y |
get/set pattern length of pattern x. non-destructive to data | |
PN.MAX x |
find the first maximum value in the pattern between the START and END for pattern x and return its index |
||
PN.MIN x |
find the first minimum value in the pattern between the START and END for pattern x and return its index |
||
PN.NEXT x |
PN.NEXT x y |
increment index of pattern x then get/set value |
|
PN.POP x |
return and remove the value from the end of pattern x (like a stack), destructive to loop length |
||
PN.PREV x |
PN.PREV x y |
decrement index of pattern x then get/set value |
|
PN.PUSH x y |
insert value y to the end of pattern x (like a stack), destructive to loop length |
||
PN.RM x y |
delete index y of pattern x , shift later values up, destructive to loop length |
||
PN.RND x |
return a value randomly selected between the start and the end position of pattern x |
||
PN.START x |
PN.START x y |
get/set the start location of pattern x , default 0 |
|
PN.WRAP x |
PN.WRAP x y |
when pattern x reaches its bounds does it wrap (0/1 ), default 1 (enabled) |
|
PROB x: ... |
potentially execute command with probability x (0-100) |
||
Q |
Q x |
Modify the queue entries | |
Q.AVG |
Q.AVG x |
Return the average of the queue | |
Q.N |
Q.N x |
The queue length | |
QT x y |
round x to the closest multiple of y (quantise) |
||
R |
generate a random number | ||
R.MAX x |
set the upper end of the range from 0 – 32767 | ||
R.MIN x |
set the lower end of the range from 0 – 32767 | ||
RAND x |
RND |
generate a random number between 0 and x inclusive |
|
RRAND x y |
RRND |
generate a random number between x and y inclusive |
|
RSH x y |
>> |
right shift x by y bits, in effect divide x by 2 to the power of y |
|
S: ... |
Place a command onto the stack | ||
S.ALL |
Execute all entries in the stack | ||
S.CLR |
Clear all entries in the stack | ||
S.L |
Get the length of the stack | ||
S.POP |
Execute the most recent entry | ||
SC.CV x y |
CV target value for the ER-301 virtual output x to value y |
||
SC.CV.OFF x y |
CV offset added to the ER-301 virtual output x |
||
SC.CV.SET x |
Set CV value for the ER-301 virtual output x |
||
SC.CV.SLEW x y |
Set the CV slew time for the ER-301 virtual output x in ms |
||
SC.TR x y |
Set trigger output for the ER-301 virtual output x to y (0-1) | ||
SC.TR.POL x y |
Set polarity of trigger for the ER-301 virtual output x to y (0-1) | ||
SC.TR.PULSE x |
SC.TR.P |
Pulse the ER-301 virtual trigger output x |
|
SC.TR.TIME x y |
Set the pulse time for the ER-301 virtual trigger x to y in ms |
||
SC.TR.TOG x |
Flip the state for the ER-301 virtual trigger output x |
||
SCALE a b x y i |
SCL |
scale i from range a to b to range x to y , i.e. i * (y - x) / (b - a) |
|
SCENE |
SCENE x |
get the current scene number, or load scene x (0-31) |
|
SCRIPT |
SCRIPT x |
$ |
get current script number, or execute script x (1-8), recursion allowed |
SKIP x: ... |
run the command every time except the x th time. |
||
STATE x |
Read the current state of input x | ||
SUB x y |
- |
subtract y from x |
|
SYNC x |
synchronizes all EVERY and SKIP counters to offset x . |
||
T |
T x |
get / set the variable T , typically used for time, default 0 |
|
TI.IN x |
reads the value of IN jack x ; default return range is from -16384 to 16383 - representing -10V to +10V; return range can be altered by the TI.IN.MAP command |
||
TI.IN.CALIB x y |
calibrates the scaling for IN jack x ; y of -1 sets the -10V point; y of 0 sets the 0V point; y of 1 sets the +10V point |
||
TI.IN.INIT x |
initializes IN jack x back to the default boot settings and behaviors; neutralizes mapping (but not calibration) |
||
TI.IN.MAP x y z |
maps the IN values for input jack x across the range y - z (default range is -16384 to 16383 - representing -10V to +10V) |
||
TI.IN.N x |
return the quantized note number for IN jack x using the scale set by TI.IN.SCALE |
||
TI.IN.QT x |
return the quantized value for IN jack x using the scale set by TI.IN.SCALE ; default return range is from -16384 to 16383 - representing -10V to +10V |
||
TI.IN.SCALE x |
select scale # y for IN jack x ; scales listed in full description |
||
TI.INIT d |
initializes all of the PARAM and IN inputs for device number d (1-8) |
||
TI.PARAM x |
TI.PRM |
reads the value of PARAM knob x ; default return range is from 0 to 16383; return range can be altered by the TI.PARAM.MAP command |
|
TI.PARAM.CALIB x y |
TI.PRM.CALIB |
calibrates the scaling for PARAM knob x ; y of 0 sets the bottom bound; y of 1 sets the top bound |
|
TI.PARAM.INIT x |
TI.PRM.INIT |
initializes PARAM knob x back to the default boot settings and behaviors; neutralizes mapping (but not calibration) |
|
TI.PARAM.MAP x y z |
TI.PRM.MAP |
maps the PARAM values for input x across the range y - z (defaults 0-16383) |
|
TI.PARAM.N x |
TI.PRM.N |
return the quantized note number for PARAM knob x using the scale set by TI.PARAM.SCALE |
|
TI.PARAM.QT x |
TI.PRM.QT |
return the quantized value for PARAM knob x using the scale set by TI.PARAM.SCALE ; default return range is from 0 to 16383 |
|
TI.PARAM.SCALE x |
TI.PRM.SCALE |
select scale # y for PARAM knob x ; scales listed in full description |
|
TI.RESET d |
resets the calibration data for TXi number d (1-8) to its factory defaults (no calibration) |
||
TI.STORE d |
stores the calibration data for TXi number d (1-8) to its internal flash memory |
||
TIME |
TIME x |
timer value, counts up in ms., wraps after 32s, can be set | |
TIME.ACT |
TIME.ACT x |
enable or disable timer counting, default 1 |
|
TO.CV x |
CV target output x ; y values are bipolar (-16384 to +16383) and map to -10 to +10 |
||
TO.CV.CALIB x |
Locks the current offset (CV.OFF ) as a calibration offset and saves it to persist between power cycles for output x . |
||
TO.CV.INIT x |
initializes CV output x back to the default boot settings and behaviors; neutralizes offsets, slews, envelopes, oscillation, etc. |
||
TO.CV.LOG x y |
translates the output for CV output x to logarithmic mode y ; y defaults to 0 (off); mode 1 is for 0-16384 (0V-10V), mode 2 is for 0-8192 (0V-5V), mode 3 is for 0-4096 (0V-2.5V), etc. |
||
TO.CV.N x y |
target the CV to note y for output x ; y is indexed in the output’s current CV.SCALE |
||
TO.CV.N.SET x y |
set the CV to note y for output x ; y is indexed in the output’s current CV.SCALE (ignoring SLEW ) |
||
TO.CV.OFF x y |
set the CV offset for output x ; y values are added at the final stage |
||
TO.CV.QT x y |
CV target output x ; y is quantized to output’s current CV.SCALE |
||
TO.CV.QT.SET x y |
set the CV for output x (ignoring SLEW ); y is quantized to output’s current CV.SCALE |
||
TO.CV.RESET x |
Clears the calibration offset for output x . |
||
TO.CV.SCALE x y |
select scale # y for CV output x ; scales listed in full description |
||
TO.CV.SET x y |
set the CV for output x (ignoring SLEW ); y values are bipolar (-16384 to +16383) and map to -10 to +10 |
||
TO.CV.SLEW x y |
set the slew amount for output x ; y in milliseconds |
||
TO.CV.SLEW.M x y |
set the slew amount for output x ; y in minutes |
||
TO.CV.SLEW.S x y |
set the slew amount for output x ; y in seconds |
||
TO.ENV x y |
This parameter essentially allows output x to act as a gate between the 0 and 1 state. Changing this value from 0 to 1 causes the envelope to trigger the attack phase and hold at the peak CV value; changing this value from 1 to 0 causes the decay stage of the envelope to be triggered. |
||
TO.ENV.ACT x y |
activates/deactivates the AD envelope generator for the CV output x ; y turns the envelope generator off (0 - default) or on (1); CV amplitude is used as the peak for the envelope and needs to be > 0 for the envelope to be perceivable |
||
TO.ENV.ATT x y |
set the envelope attack time to y for CV output x ; y in milliseconds (default 12 ms) |
||
TO.ENV.ATT.M x y |
set the envelope attack time to y for CV output x ; y in minutes |
||
TO.ENV.ATT.S x y |
set the envelope attack time to y for CV output x ; y in seconds |
||
TO.ENV.DEC x y |
set the envelope decay time to y for CV output x ; y in milliseconds (default 250 ms) |
||
TO.ENV.DEC.M x y |
set the envelope decay time to y for CV output x ; y in minutes |
||
TO.ENV.DEC.S x y |
set the envelope decay time to y for CV output x ; y in seconds |
||
TO.ENV.EOC x n |
fires a PULSE at the End of Cycle to the unit-local trigger output ‘n’ for the envelope on CV output x ; n refers to trigger output 1-4 on the same TXo as CV output ‘y’ |
||
TO.ENV.EOR x n |
fires a PULSE at the End of Rise to the unit-local trigger output ‘n’ for the envelope on CV output x ; n refers to trigger output 1-4 on the same TXo as CV output ‘y’ |
||
TO.ENV.LOOP x y |
causes the envelope on CV output x to loop for y times; a y of 0 will cause the envelope to loop infinitely; setting y to 1 (default) disables looping and (if currently looping) will cause it to finish its current cycle and cease |
||
TO.ENV.TRIG x |
triggers the envelope at CV output x to cycle; CV amplitude is used as the peak for the envelope and needs to be > 0 for the envelope to be perceivable |
||
TO.INIT d |
initializes all of the TR and CV outputs for device number d (1-8) |
||
TO.KILL d |
cancels all TR pulses and CV slews for device number d (1-8) |
||
TO.M d y |
sets the 4 independent metronome intervals for device d (1-8) to y in milliseconds; default 1000 |
||
TO.M.ACT d y |
sets the active status for the 4 independent metronomes on device d (1-8) to y (0 /1 ); default 0 (disabled) |
||
TO.M.BPM d y |
sets the 4 independent metronome intervals for device d to y in Beats Per Minute |
||
TO.M.COUNT d y |
sets the number of repeats before deactivating for the 4 metronomes on device d to y ; default 0 (infinity) |
||
TO.M.M d y |
sets the 4 independent metronome intervals for device d to y in minutes |
||
TO.M.S d y |
sets the 4 independent metronome intervals for device d to y in seconds; default 1 |
||
TO.M.SYNC d |
synchronizes the 4 metronomes for device number d (1-8) |
||
TO.OSC x y |
targets oscillation for CV output x to y with the portamento rate determined by the TO.OSC.SLEW value; y is 1v/oct translated from the standard range (1-16384); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.CTR x y |
centers the oscillation on CV output x to y ; y values are bipolar (-16384 to +16383) and map to -10 to +10 |
||
TO.OSC.CYC x y |
targets the oscillator cycle length to y for CV output x with the portamento rate determined by the TO.OSC.SLEW value; y is in milliseconds |
||
TO.OSC.CYC.M x y |
targets the oscillator cycle length to y for CV output x with the portamento rate determined by the TO.OSC.SLEW value; y is in minutes |
||
TO.OSC.CYC.M.SET x y |
sets the oscillator cycle length to y for CV output x (ignores CV.OSC.SLEW ); y is in minutes |
||
TO.OSC.CYC.S x y |
targets the oscillator cycle length to y for CV output x with the portamento rate determined by the TO.OSC.SLEW value; y is in seconds |
||
TO.OSC.CYC.S.SET x y |
sets the oscillator cycle length to y for CV output x (ignores CV.OSC.SLEW ); y is in seconds |
||
TO.OSC.CYC.SET x y |
sets the oscillator cycle length to y for CV output x (ignores CV.OSC.SLEW ); y is in milliseconds |
||
TO.OSC.FQ x y |
targets oscillation for CV output x to frequency y with the portamento rate determined by the TO.OSC.SLEW value; y is in Hz; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.FQ x y |
sets oscillation for CV output x to frequency y (ignores CV.OSC.SLEW ); y is in Hz; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.LFO x y |
targets oscillation for CV output x to LFO frequency y with the portamento rate determined by the TO.OSC.SLEW value; y is in mHz (millihertz: 10^-3 Hz); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.LFO.SET x y |
sets oscillation for CV output x to LFO frequency y (ignores CV.OSC.SLEW ); y is in mHz (millihertz: 10^-3 Hz); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.N x y |
targets oscillation for CV output x to note y with the portamento rate determined by the TO.OSC.SLEW value; see quantization scale reference for y ; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.N.SET x y |
sets oscillation for CV output x to note y (ignores CV.OSC.SLEW ); see quantization scale reference for y ; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.PHASE x y |
sets the phase offset of the oscillator on CV output x to y (0 to 16383); y is the range of one cycle |
||
TO.OSC.QT x y |
targets oscillation for CV output x to y with the portamento rate determined by the TO.OSC.SLEW value; y is 1v/oct translated from the standard range (1-16384) and quantized to current OSC.SCALE ; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.QT.SET x y |
set oscillation for CV output x to y (ignores CV.OSC.SLEW ); y is 1v/oct translated from the standard range (1-16384) and quantized to current OSC.SCALE ; a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.RECT x y |
rectifies the polarity of the oscillator for output x to y ; range for y is -2 to 2; default is 0 (no rectification); 1 & -1 are partial rectification - omitting all values on the other side of the sign; 2 & -2 are full rectification - inverting values from the other pole |
||
TO.OSC.SCALE x y |
select scale # y for CV output x ; scales listed in full description |
||
TO.OSC.SET x y |
set oscillation for CV output x to y (ignores CV.OSC.SLEW ); y is 1v/oct translated from the standard range (1-16384); a value of 0 disables oscillation; CV amplitude is used as the peak for oscillation and needs to be > 0 for it to be perceivable |
||
TO.OSC.SLEW x y |
sets the frequency slew time (portamento) for the oscillator on CV output x to y ; y in milliseconds |
||
TO.OSC.SLEW.M x y |
sets the frequency slew time (portamento) for the oscillator on CV output x to y ; y in minutes |
||
TO.OSC.SLEW.S x y |
sets the frequency slew time (portamento) for the oscillator on CV output x to y ; y in seconds |
||
TO.OSC.SYNC x |
resets the phase of the oscillator on CV output x (relative to TO.OSC.PHASE ) |
||
TO.OSC.WAVE x y |
set the waveform for output x to y ; y values range 0-4999 ; values translate to sine (0), triangle (1000), saw (2000), pulse (3000), or noise (4000); oscillator shape between values is a blend of the pure waveforms |
||
TO.OSC.WIDTH x y |
sets the width of the pulse wave on output x to y ; y is a percentage of total width (0 to 100); only affects waveform 3000 |
||
TO.TR x y |
sets the TR value for output x to y (0/1) |
||
TO.TR.INIT x |
initializes TR output x back to the default boot settings and behaviors; neutralizes metronomes, dividers, pulse counters, etc. |
||
TO.TR.M x y |
sets the independent metronome interval for output x to y in milliseconds; default 1000 |
||
TO.TR.M.ACT x y |
sets the active status for the independent metronome for output x to y (0 /1 ); default 0 (disabled) |
||
TO.TR.M.BPM x y |
sets the independent metronome interval for output x to y in Beats Per Minute |
||
TO.TR.M.COUNT x y |
sets the number of repeats before deactivating for output x to y ; default 0 (infinity) |
||
TO.TR.M.M x y |
sets the independent metronome interval for output x to y in minutes |
||
TO.TR.M.MUL x y |
multiplies the M rate on TR output x by y ; y defaults to 1 - no multiplication |
||
TO.TR.M.S x y |
sets the independent metronome interval for output x to y in seconds; default 1 |
||
TO.TR.M.SYNC x |
synchronizes the PULSE for metronome on TR output number x |
||
TO.TR.POL x y |
sets the polarity for TR output n |
||
TO.TR.PULSE x |
TO.TR.P |
pulses the TR value for output x for the duration set by TO.TR.TIME/S/M |
|
TO.TR.PULSE.DIV x y |
TO.TR.P.DIV |
sets the clock division factor for TR output x to y |
|
TO.TR.PULSE.MUTE x y |
TO.TR.P.MUTE |
mutes or un-mutes TR output x ; y is 1 (mute) or 0 (un-mute) |
|
TO.TR.TIME x y |
sets the time for TR.PULSE on output n ; y in milliseconds |
||
TO.TR.TIME.M x y |
sets the time for TR.PULSE on output n ; y in minutes |
||
TO.TR.TIME.S x y |
sets the time for TR.PULSE on output n ; y in seconds |
||
TO.TR.TOG x |
toggles the TR value for output x |
||
TO.TR.WIDTH x y |
sets the time for TR.PULSE on output n based on the width of its current metronomic value; y in percentage (0-100) |
||
TOSS |
randomly return 0 or 1 |
||
TR x |
TR x y |
Set trigger output x to y (0-1) | |
TR.POL x |
TR.POL x y |
Set polarity of trigger output x to y (0-1) | |
TR.PULSE x |
TR.P |
Pulse trigger output x | |
TR.TIME x |
TR.TIME x y |
Set the pulse time of trigger x to y ms | |
TR.TOG x |
Flip the state of trigger output x | ||
V x |
converts a voltage to a value usable by the CV outputs (x between 0 and 10 ) |
||
VV x |
converts a voltage to a value usable by the CV outputs (x between 0 and 1000 , 100 represents 1V) |
||
W x: ... |
run the command while condition x is true | ||
WRAP x y z |
WRP |
limit the value x to the range y to z inclusive, but with wrapping |
|
WS.CUE x |
Go to a cuepoint relative to the playhead position. 0 retriggers the current location. 1 jumps to the next cue forward. -1 jumps to the previous cue in the reverse. These actions are relative to playback direction such that 0 always retriggers the most recently passed location |
||
WS.LOOP x |
Set the loop state on/off. 0 is off. Any other value turns loop on |
||
WS.PLAY x |
Set playback state and direction. 0 stops playback. 1 sets forward motion, while -1 plays in reverse |
||
WS.REC x |
Set recording mode. 0 is playback only. 1 sets overdub mode for additive recording. -1 sets overwrite mode to replace the tape with your input |
||
WW.END x |
Set the loop end position (0-15) | ||
WW.MUTE1 x |
Mute trigger 1 (0 = on, 1 = mute) | ||
WW.MUTE2 x |
Mute trigger 2 (0 = on, 1 = mute) | ||
WW.MUTE3 x |
Mute trigger 3 (0 = on, 1 = mute) | ||
WW.MUTE4 x |
Mute trigger 4 (0 = on, 1 = mute) | ||
WW.MUTEA x |
Mute CV A (0 = on, 1 = mute) | ||
WW.MUTEB x |
Mute CV B (0 = on, 1 = mute) | ||
WW.PATTERN x |
Change pattern (0-15) | ||
WW.PMODE x |
Set the loop play mode (0-5) | ||
WW.POS x |
Cut to position (0-15) | ||
WW.PRESET x |
Recall preset (0-7) | ||
WW.QPATTERN x |
Change pattern (0-15) after current pattern ends | ||
WW.START x |
Set the loop start position (0-15) | ||
WW.SYNC x |
Cut to position (0-15) and hard-sync the clock (if clocked internally) | ||
X |
X x |
get / set the variable X , default 0 |
|
Y |
Y x |
get / set the variable Y , default 0 |
|
Z |
Z x |
get / set the variable Z , default 0 |
|
^ x y |
bitwise xor x ^ y |
||
| x y |
bitwise or x |
||
~ x |
bitwise not, i.e.: inversion of x |
Missing documentation
G.XYP
, G.XYP.X
, G.XYP.Y
, IN.CAL.RESET
, P.ADD
, P.ADDW
, P.SUB
, P.SUBW
, PARAM.CAL.RESET
, PN.ADD
, PN.ADDW
, PN.SUB
, PN.SUBW
, TIF
Changelog
v3.0
- NEW: grid integration / grid visualizer / grid control mode
- NEW: multiline copy/paste and editing
- NEW: new keybindings to move by words
- NEW: undo in script editing
- NEW: i2c support for ER-301
- NEW: i2c support for 16n Faderbank
- NEW: i2c support for Matrixarchate
- NEW: i2c support for W/
- NEW: new op: ?
- NEW: new ops: P.MIN, PN.MIN, P.MAX, PN.MAX, P.RND, PN.RND, P.+, PN.+, P.-, PN.-. P.+W, PN.+W, P.-W, PN.-W
- NEW: new Telex ops: TO.CV.CALIB, TO.ENV
- NEW: new Kria ops: KR.CV, KR.MUTE, KR.TMUTE, KR.CLK, ME.CV
- NEW: new aliases: $, RND, RRND, WRP, SCL
- FIX: i2c initialization delayed to account for ER-301 bootup
- FIX: last screen saved to flash
- FIX: knob jitter when loading/saving scenes reduced
- FIX: duplicate commands not added to history
- FIX:
SCALE
precision improved - FIX:
PARAM
set properly when used in the init script - FIX:
PARAM
andIN
won’t reset to 0 afterINIT.DATA
- FIX:
PN.HERE
,P.POP
,PN.POP
will update the tracker screen - FIX:
P.RM
was 1-based, now 0-based - FIX:
P.RM
/PN.RM
will not change pattern length if deleting outside of length range - FIX:
JI
op fixed - FIX:
TIME
andLAST
are now 1ms accurate - FIX:
RAND
/RRAND
will properly work with large range values - FIX:
L .. 32767
won’t freeze - FIX: I now accessible to child SCRIPTS
v2.2
- NEW: added a cheat sheet PDF
- NEW: new bitwise ops: &, |, ^, ~, BSET, BCLR, BGET
- NEW: new ops
PARAM.SCALE min max
andIN.SCALE min max
to add static scaling to inputs - NEW: blanking screensaver after 90 minutes of keyboard inactivity, any key to wake
- NEW: new op: CHAOS chaotic sequence generator. Control with CHAOS.ALG and CHAOS.R
- NEW: new op family:
INIT
, to clear device state - NEW: new ops:
R
,R.MIN
,R.MAX
programmable RNG - IMP: profiling code (optional, dev feature)
- IMP: screen now redraws only lines that have changed
- FIX: multiply now saturates at limits, previous behaviour returned 0 at overflow
- FIX: entered values now saturate at int16 limits
- FIX: reduced flash memory consumption by not storing TEMP script
- FIX:
I
now carries acrossDEL
commands - FIX: removed TEMP script allocation in flash
- FIX: corrected functionality of JI op for 1volt/octave tuning and removed octave-wrapping behaviour (now returns exactly the entered ratio)
- FIX: reduced latency of
IN
op
v2.1
- BREAKING: the
I
variable is now scoped to theL
loop, and does not exist outside of an execution context. Scripts usingI
as a general-purpose variable will be broken. - FIX:
SCENE
will not run fromINIT
script during scene load. - NEW: Tracker data entry overhaul. Type numbers, press enter to commit.
- NEW: new op:
BPM
to get milliseconds per beat in given BPM - NEW: script lines can be disabled / enabled with ctrl-/
- NEW: shift-enter in scene write mode now inserts a line
- NEW: new ops:
LAST x
for the last time scriptx
was called - NEW:
SCRIPT
with no arguments gets the current script number. - FIX:
AVG
andQ.AVG
now round up properly - NEW: new op:
BREAK
to stop the remainder of the script - NEW: new mod:
W [condition]: [statement]
will executestatement
as long ascondition
is true (up to an iteration limit). - NEW: new mods:
EVERY x:
,SKIP x:
,OTHER:
to alternately execute or not execute a command. - NEW: new op:
SYNC x
will synchronize allEVERY
andSKIP
line to the same step. - NEW: new feature: @ - the turtle. Walks around the pattern grid. Many ops, see documentation.
- OLD: ctrl-F1 to F8 mute/unmute scripts.
- NEW: ctrl-F9 enables/disables METRO.
- FIX: recursive delay fix. Now you can
1: DEL 500: SCRIPT 1
for temporal recursion. - FIX: KILL now clears TR output as well as disabling the METRO script.
- FIX: if / else conditions no longer transcend their script
- IMP: functional exectuion stack for
SCRIPT
operations
v2.0.1
- FIX: update IRQ masking which prevents screen glitches and crashing under heavy load
v2.0
- BREAKING: remove
II
op. Ops that required it will now work with out it. (e.g.II MP.PRESET 1
will become justMP.PRESET 1
) - BREAKING: merge the
MUTE
andUNMUTE
ops. NowMUTE x
will return the mute status for triggerx
(0
is unmuted,1
is muted), andMUTE x y
will set the mute for triggerx
(y = 0
to unmute,y = 1
to mute) - BREAKING: remove unused Meadowphysics ops:
MP.SYNC
,MP.MUTE
,MP.UNMUTE
,MP.FREEZE
,MP.UNFREEZE
- BREAKING: rename Ansible Meadowphysics ops to start with
ME
- NEW: sub commands, use a
;
separator to run multiple commands on a single line, e.g.X 1; Y 2
- NEW: key bindings rewritten
- NEW: aliases:
+
forADD
,-
forSUB
,*
forMUL
,/
forDIV
,%
forMOD
,<<
forLSH
,>>
forRSH
,==
forEQ
,!=
forNE
,<
forLT
,>
forGT
,<=
forLTE
,>=
forGTE
,!
forEZ
,&&
forAND
,||
forOR
,PRM
forPARAM
,TR.P
forTR.PULSE
- NEW: new ops:
LTE
(less than or equal), andGTE
(greater than or equal) - NEW: new pattern ops:
PN.L
,PN.WRAP
,PN.START
,PN.END
,PN.I
,PN.HERE
,PN.NEXT
,PN.PREV
,PN.INS
,PN.RM
,PN.PUSH
andPN.POP
- NEW: USB disk loading and saving works at any time
- NEW:
M
limited to setting the metronome speed to 25ms, addedM!
to allow setting the metronome at unsupported speeds as low as 2ms - NEW: TELEX Aliases:
TO.TR.P
forTO.TR.PULSE
(plus all sub-commands) andTI.PRM
forTI.PARAM
(plus all sub-commands) - NEW: TELEX initialization commands:
TO.TR.INIT n
,TO.CV.INIT n
,TO.INIT x
,TI.PARAM.INIT n
,TI.IN.INIT n
, andTI.INIT x
- IMP: new Ragel parser backend
- IMP: script recursion enhanced, maximum recursion depth is 8, and self recursion is allowed
- IMP: removed the need to prefix
:
and;
with a space, e.g.IF X : TR.PULSE 1
becomesIF X: TR.PULSE
- IMP:
AND
andOR
now work as boolean logic, rather than bitwise,XOR
is an alias forNE
- FIX: divide by zero errors now explicitly return a 0 (e.g.
DIV 5 0
now returns 0 instead of -1), previously the behaviour was undefined and would crash the simulator - FIX: numerous crashing bugs with text entry
- FIX:
i2c
bus crashes under highM
times with external triggers - FIX:
P.I
andPN.I
no longer set values longer than allowed - FIX:
VV
works correctly with negative values
v1.4.1
- NEW: added Ansible remote commands
LV.CV
andCY.CV
- NEW: Added TELEX Modules Support for the TXi and the TXo
- NEW: 75 New Operators Across the Two Modules
- NEW: Supports all basic Teletype functions (add
TI
andTO
to the commands you already know) - NEW: Extended functionality allows for additional capabilities for existing functions
- NEW: Experimental input operators add capabilities such as input range mapping and quantization
- NEW: Experimental output operators add oscillators, envelopes, independent metronomes, pulse dividing, etc.
- NEW: Full List of Methods Found and Maintained Here
v1.2.1
- NEW: Just Friends ops:
JF.GOD
,JF.MODE
,JF.NOTE
,JF.RMODE
,JF.RUN
,JF.SHIFT
,JF.TICK
,JF.TR
,JF.TUNE
,JF.VOX
,JF.VTR
v1.2
- NEW: Ansible support added to ops:
CV
,CV.OFF
,CV.SET
,CV.SLEW
,STATE
,TR
,TR.POL
,TR.PULSE
,TR.TIME
,TR.TOG
- NEW:
P.RM
will also return the value removed - NEW:
ER
op - IMP: a
TR.TIME
of 0 will disable the pulse - IMP:
O.DIR
renamed toO.INC
, it’s the value by whichO
is incremented when it is accessed - IMP:
IF
,ELIF
,ELSE
status is reset on each script run - IMP: key repeat now works for all keypresses
- FIX:
FLIP
won’t interfere with the value ofO
- FIX: the
O
op now returns it’s set value before updating itself - FIX: the
DRUNK
op now returns it’s set value before updating itself - FIX:
P.START
andP.END
were set to 1 when set with too large values, now are set to 63 - FIX:
CV.SLEW
is correctly initialised to 1 for all outputs - FIX: several bugs where pattern length wasn’t updated in track mode
- FIX: fixed
[
and]
not updating values in track mode
v1.1
- NEW: USB flash drive read/write
- NEW:
SCRIPT
op for scripted execution of other scripts! - NEW:
MUTE
andUNMUTE
ops for disabling trigger input - NEW: hotkeys for
MUTE
toggle per input (meta-shift-number) - NEW: screen indication in live mode for
MUTE
status - NEW:
SCALE
op for scaling number from one range to another - NEW:
JI
op just intonation helper - NEW:
STATE
op to read current state of input triggers 1-8 (low/high = 0/1) - NEW: keypad executes scripts (works for standalone USB keypads and full-sized keyboards)
- NEW:
KILL
op clears delays, stack, CV slews, pulses - NEW: hotkey meta+ESC executes
KILL
- NEW:
ABS
op absolute value, single argument - NEW:
FLIP
op variable which changes state (0/1) on each read - NEW: logic ops:
AND
,OR
,XOR
- NEW:
O
ops:O.MIN
,O.MAX
,O.WRAP
,O.DIR
for counter range control - NEW:
DRUNK
ops:DRUNK.MIN
,DRUNK.MAX
,DRUNK.WRAP
for range control - NEW:
TR.POL
specifies the polarity ofTR.PULSE
- NEW: if powered down in tracker mode, will power up in tracker mode
- IMP:
TR.PULSE
retrigger behaviour now predictable - IMP: mode switch keys more consistent (not constantly resetting to live mode)
- FIX: bug in command history in live mode
- FIX:
EXP
op now exists - FIX:
P
andPN
parse error - FIX: possible crash on excess length line entry
- FIX:
CV
wrapping with negativeCV.OFF
values - FIX: INIT script executed now on keyboardless scene recall
- FIX:
Q.AVG
overflow no more - FIX:
P.PUSH
will fully fill a pattern - FIX:
CV.SET
followed by slewed CV in one command works - FIX:
DEL 0
no longer voids command
v1.0